在DoS攻击下的相互连接系统的攻击弹性故障检测
相关实验视频
Updated: Jul 20, 2026

08:05
Design and Analysis for Fall Detection System Simplification
Published on: April 6, 2020
10.7K
Qidong Liu1, Yue Long2, Tieshan Li2
1School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China.
ISA transactions
|March 30, 2024
概括
本研究介绍了一种弹性故障检测方案,以应对网络系统中的拒绝服务 (DoS) 攻击. 这种创新方法节约了网络资源,同时提高了网络空间应用程序的故障检测准确性.
科学领域:
- 网络安全 网络安全
- 控制系统工程 控制系统工程
- 网络化系统 网络化系统
背景情况:
- 不断扩大的网络空间应用需要强有力的安全措施来应对网络攻击.
- 拒绝服务 (DoS) 攻击对系统安全和操作完整性构成重大威胁.
- 现有的故障检测方法可能容易受到复杂,动态的网络威胁.
研究的目的:
- 为非线性互联系统开发一种弹性动态事件触发故障检测方案.
- 在DoS攻击下解决故障检测过器和事件触发传输机制的共同设计.
- 为了在面对网络攻击时增强系统安全性和性能.
主要方法:
- 交换式故障检测过器和动态事件触发传输机制的联合设计.
- 将信号频率信息纳入过器设计.
- 为增强系统性能开发线性可解决条件.
- 进行比较模拟实验以验证拟议方案的有效性.
主要成果:
- 拟议的方案证明了对DoS攻击的弹性.
- 动态事件触发机制有效地节约了网络资源.
- 观察到对特定频率故障信号的优异检测能力.
- 通过线性可解决条件实现了增强的系统性能.
结论:
- 开发的故障检测机制为保护网络系统免受DoS攻击提供了有效的解决方案.
- 该方法平衡了网络资源的节约与提高故障检测性能.
- 这项工作有助于在互联系统中推进弹性网络安全.
更多相关视频
相关概念视频
Distribution Reliability and Automation
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
Power System Three-Phase Short Circuits
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Radial System Protection
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
Zones of Protection
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...