概括
评估了空气库宁净化厂的饮用水质量. 虽然大多是安全的,但总大肠杆菌和铁水平升高,突出了改善水处理和公共卫生意识的领域.
科学领域:
- 环境科学 环境科学
- 公共卫生 公共卫生
- 水质管理水质管理
背景情况:
- 一项卫生调查评估了马来西亚Air Kuning净化厂14个点的饮用水质量.
- 该研究旨在确保为公共卫生提供安全饮用水的持续供应.
- 根据国家饮用水标准 (NDWQS) 评估的水质参数.
研究的目的:
- 检查饮用水的物理,微生物学和化学参数.
- 根据NDWQS,对每个采样地点的水质进行分类.
- 使用主要成分分析 (PCA) 了解水质的空间变化.
主要方法:
- 水样进行了现场和实验室分析,以确定包括pH值,度,,大肠杆菌,大肠杆菌总量,硬度,铁,,,,和在内的参数.
- 按照美国公共卫生协会 (APHA) 的标准测试程序进行了测试.
- 环境测量技术,主要组件分析 (PCA) 用于分析空间变化.
主要成果:
- 大多数水质参数符合NDWQS安全限值,除了总胆固醇和铁 (Fe).
- PCA确定了度,总大肠杆菌,大肠杆菌, (Na) 和 (Al) 是导致河流摄入口饮用水污染的关键因素.
- 在处理过程后,水质被认为是安全的.
结论:
- 来自所有采样点的处理水都符合饮用安全标准.
- 对净化厂水质的持续评估对公共健康至关重要.
- 社区对饮用水质量的认识对于公众健康和环境保护至关重要.
相关概念视频
pH
The potential of hydrogen (pH) is a measure of the acidity or basicity of a water-based solution determined by the concentration of hydronium ions (H3O+). In one liter of pure water at neutral pH, there are 1×10−7 moles of hydronium ions. However, the extensive range of hydronium ion concentrations present in water-based solutions makes measuring pH in moles cumbersome. Therefore, a pH scale was developed to convert moles of hydronium ions into the negative logarithm of the hydronium ion...
Precipitation and Co-precipitation
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
Quality of Water
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
Testing Water Quality
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...