从霍尔特和可穿戴腕带跟踪潮体积,监测心电图
IEEE journal of biomedical and health informatics
|April 1, 2024
概括
本研究引入了一种使用心电图 (ECG) 信号追踪潮体积 (TV) 的新方法. 这种基于心电图衍生的呼吸 (EDR) 幅度的方法显示,它有望通过可穿戴设备监测呼吸变化.
科学领域:
- 生物医学工程 生物医学工程
- 心脏病学 心脏病学
- 呼吸系统医学 呼吸系统医学
背景情况:
- 追踪潮体积 (TV) 对于呼吸监测至关重要.
- 现有的方法可能需要校准或侵入性程序.
- 电脑心电图信号包含除了心脏活动之外的生理信息.
研究的目的:
- 开发和验证使用心电图衍生呼吸 (EDR) 信号跟踪电视变化的新方法.
- 评估电视估计的未校准和个性化校准方法的性能.
- 评估使用定制可穿戴腕带用于电视监控的可行性.
主要方法:
- 研究了来自不同EDR形态和振幅估计技术的9个振幅EDR (AEDR) 信号.
- 提出了一种使用线性模型与AEDR信号的个性化校准方法.
- 使用商用Holter显示器和定制可穿戴腕带与参考电视相对应的验证方法.
主要成果:
- 个性化校准方法实现了较低的中位误差 (-3.48%为霍尔特,0.28%为腕带).
- 未校准的方法显示中位数相关性>0.8,而个性化校准方法超过0.9.
- 这些方法在跟踪大型电视变化方面表现出可靠性,适用于睡眠呼吸暂停等疾病.
结论:
- 从心电图上可以有效地追踪电视变化,使用传统设备和可穿戴设备.
- 个性化校准可提高从心电图的电视估计的准确性.
- 开发的方法显示了非侵入性呼吸系统监测的潜力,特别是重要呼吸系统事件.
更多相关视频
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
8.6K
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
24.3K
相关概念视频
Pulse rhythm
795
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
795
Electrocardiogram
2.3K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.3K
Equipments Used To Measure Blood Pressure
966
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
966