在29个三级医院的血液透析护士中,机器报警疲劳
Chaonan Sun1, Meirong Bao2, Congshan Pu1
1School of Nursing, Dalian Medical University, Dalian, Liaoning, China.
Applied clinical informatics
|April 1, 2024
概括
机器报警疲劳是宁省血液透析护士的一个中度问题. 经验,患者负担和倦怠等因素显著影响这种疲劳,需要改进管理系统.
科学领域:
- 护理 护理 护理
- 医疗保健管理的管理
- 职业健康 职业健康 职业健康
背景情况:
- 机器报警疲劳在重症监护机构中越来越令人担忧.
- 血液透析护士面临着独特的挑战,因为频繁和复杂的警报.
- 了解导致警报疲劳的因素对于患者安全和护士福祉至关重要.
研究的目的:
- 评估血液透析护士中机器报警疲劳的患病率和影响因素.
- 为了确定人口统计学,工作负载和与燃烧相关的预测因素,在这个人群中预测警报疲劳.
- 提供基于证据的建议,以减轻血液透析单位的警报疲劳.
主要方法:
- 一项涉及宁省29家三级医院460名血液透析护士的横截面研究.
- 使用了经过验证的问卷,包括警报疲劳量表,NASA-TLX和Maslach Burnout Inventory.
- 员工方便抽样用于参与者招聘.
主要成果:
- 整体机器报警疲劳得分为17.04±3.21,表明中等水平.
- 与警报疲劳相关的重要因素包括多年的经验,患者与护士的比例,专业培训,健康状况,情绪疲劳和工作负担.
- 多年经验显示出负相关性,而患者负载和工作负载显示出与警报疲劳的正相关性.
结论:
- 机器报警疲劳在血液透析护士中适度流行,受到经验,工作量和倦怠的影响.
- 建议包括实施机器报警管理系统,个性化报警设置和优化人员配置.
- 解决警报疲劳对于提高护士福祉,专业发展和患者护理质量至关重要.
相关概念视频
Dialysis
307
Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
307
Errors occurring during blood pressure monitoring
720
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
720
Healthcare Associated Infections II: Preventive Measures
2.6K
Essential infection prevention measures are based on the knowledge of the infection chain, the modes of transmission in healthcare settings, and the use of the best practices in all healthcare settings. Compulsory public reporting of healthcare-associated infection rates is needed to allow individuals and the community to make informed choices regarding selecting a healthcare facility.
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
2.6K
Assessment of apical radial pulse
740
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
740
Special considerations while measuring blood pressure
722
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
722
Equipments Used To Measure Blood Pressure
966
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
966