Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

705
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
705
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

585
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
585
Neural Regulation of Blood Pressure01:18

Neural Regulation of Blood Pressure

2.8K
The neural regulation of blood pressure involves intricate interactions between the autonomic nervous system (ANS) and cardiovascular system, ensuring adequate perfusion of tissues. This regulation primarily occurs through baroreceptor and chemoreceptor reflexes, involving both short-term and long-term mechanisms.
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
2.8K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

966
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
966
Sites for measruring blood pressure01:21

Sites for measruring blood pressure

1.7K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.7K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Accelerating P300-based neurofeedback training for attention enhancement using iterative learning control: a randomised controlled trial.

Journal of neural engineering·2024
Same author

Adaptive P300-Based Brain-Computer Interface for Attention Training: Protocol for a Randomized Controlled Trial.

JMIR research protocols·2023
Same author

A multi-component model of the dynamics of salt-induced hypertension in Dahl-S rats.

BMC physiology·2009
查看所有相关文章

相关实验视频

Updated: Jun 29, 2025

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
09:56

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice

Published on: February 14, 2021

5.0K

关于测序方法对巴罗反射灵敏度估计的准确性

Hasana Bagnall-Hare1, Violeta I McLoone2, John V Ringwood3

  • 1Department of Electronic Engineering, Maynooth University, Maynooth, Co. Kildare, Ireland. hasana.bagnallhare.2016@mumail.ie.

Physical and engineering sciences in medicine
|April 2, 2024
PubMed
概括
此摘要是机器生成的。

对于巴罗反射灵敏度估计的序列方法可能不准确. 这些方法可能会引入显著的偏差,即使经过仔细的数据选择,由于在没有黄金标准的情况下量化准确性的局限性.

关键词:
巴罗反射灵敏度的敏感性序列方法 序列方法系统识别 系统识别

更多相关视频

Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
11:08

Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.

Published on: February 14, 2018

10.2K
Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats
06:30

Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats

Published on: September 11, 2018

7.8K

相关实验视频

Last Updated: Jun 29, 2025

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
09:56

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice

Published on: February 14, 2021

5.0K
Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
11:08

Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.

Published on: February 14, 2018

10.2K
Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats
06:30

Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats

Published on: September 11, 2018

7.8K

科学领域:

  • 身体生理学 身体生理学
  • 生物医学工程 生物医学工程
  • 心血管研究研究心血管研究

背景情况:

  • 准确的非侵入性巴罗反射灵敏度 (BRS) 估计对于理解心血管调节至关重要.
  • 缺乏最终的黄金标准使现有的BRS估计技术的验证变得复杂.
  • 序列方法广泛用于BRS估计,依赖于识别血压和RR间隔数据中的相关序列.

研究的目的:

  • 为了评估序列方法的准确性,用于巴罗反射灵敏度估计.
  • 从系统识别角度分析序列方法引入的潜在偏差.
  • 用模拟和现实世界的生理数据来评估序列方法的性能.

主要方法:

  • 应用了系统识别原则来分析序列方法.
  • 使用序列方法对从数学模型中生成的数据估计了巴罗反射灵敏度.
  • 测序方法的准确性也使用自发的巴罗反射数据进行了评估.

主要成果:

  • 序列方法证明了可能引入显著偏差的巴罗反射灵敏度估计.
  • 在BRS估计中观察到偏差,即使应用了细致的序列选择标准.
  • 该研究强调了序列方法准确度量化的局限性.

结论:

  • 序列方法虽然很受欢迎,但由于固有的偏差,可能无法提供准确的巴罗反射灵敏度估计.
  • 需要进行进一步的研究,以开发更可靠的非侵入性巴罗反射灵敏度评估方法.
  • 这些发现强调了批判性评估BRS估计技术,特别是序列方法的重要性.