关于短距离非视线紫外线通信通道脉冲响应的理论和实验研究

Optics express
|April 4, 2024
PubMed
概括

紫外线通信 (UVC) 通道的新理论模型提高了非视线 (NLOS) 场景的准确性和速度. 与蒙特卡洛方法相比,这种单散射模型显著减少了计算时间,经过实验验证.

相关概念视频

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
2.6K
Impulse Response01:17

Impulse Response

The impulse response is the system's reaction to an input impulse. In an RC circuit, the voltage source is the input, and the capacitor's voltage is the output. The system's state and output response before and after input excitation are distinctly defined.
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is...
256
Boundary Conditions: Lossless Lines01:21

Boundary Conditions: Lossless Lines

Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
93
The Electromagnetic Spectrum01:24

The Electromagnetic Spectrum

Electromagnetic waves are categorized according to their wavelengths and frequencies, giving the electromagnetic spectrum. These waves are classified as radio, infrared, ultraviolet, etc. Radio waves refer to electromagnetic radiation with wavelengths ranging from millimeters to kilometers. Radio waves are commonly used for audio communications (i.e., radios) and typically result from an alternating current in the wires of a broadcast antenna. They cover a broad wavelength range and are used...
17.6K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.4K