在腕带中量化了209种多二相干物,以评估拆除工人暴露的差异
Stephanie C Hammel1, Marie Frederiksen1
1National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark.
Environmental science & technology
|April 4, 2024
概括
腕带有效地监测了拆除工人的多二 (PCB) 暴露. 分析显示,特定的任务,如切割密封剂,导致PCB含量更高,强调总的同源监测.
科学领域:
- 环境科学 环境科学
- 职业健康 职业健康 职业健康
- 分析化学 分析化学
背景情况:
- 丹麦的社会住房因室内高化双 (PCB) 含量而面临拆除.
- 评估工人在拆除过程中暴露于PCB的情况对于职业安全至关重要.
研究的目的:
- 建立和验证一种方法,使用腕带分析所有209个PCB同胞.
- 为了确定突出的PCB同源,并评估拆除任务之间的暴露差异.
主要方法:
- 46名拆除工人在工作日穿着预先清洗的腕带.
- 微波辅助提取和GC-MS/MS用于分析手腕带中的PCB.
- 分析的重点是所有209个PCB同源,而不仅仅是常见的指标.
主要成果:
- -CBs是占主导地位的PCB组,其中PCB-66,-44和-70是最丰富的.
- 切割含PCB密封剂的工人显示了最高的PCB度 (1963 ng/g).
- 腕带检测到比以前在空气或血清样本中报告的更广泛的PCB.
结论:
- 总同源分析对于准确的PCB暴露评估在拆除过程中至关重要.
- 腕带是监测在拆除工作期间职业PCB暴露的宝贵工具.
更多相关视频
相关概念视频
Complexometric Titration: Overview
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free indicator. The...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Complexometric Titration: Ligands
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...


