不连续大气压接口的开发和表征 - 双压室微型质谱仪
Hua Li1, Qi Jing-Hao1, Li Ya-Qing2
1School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
Analytical biochemistry
|April 4, 2024
概括
一个带有不连续大气压接口的新型微型质谱仪,可以提高十倍以上的检测效率. 这种紧的仪器增强了药物检测极限,并减少了更广泛应用的尺寸和功耗.
科学领域:
- 分析化学 分析化学
- 发展工具发展工具
- 质谱测量质量谱测量
背景情况:
- 微型质谱仪对于实时分析至关重要,因为它们的便携性.
- 提高性能是推动质谱微型化的关键.
- 现有的设计往往面临检测效率和复杂性的局限性.
研究的目的:
- 开发一种新的微型质谱仪,提高检测效率和便携性.
- 为了简化设计,提高微型质谱仪的故障耐受性.
- 为了实现快速药物分析的较低检测极限.
主要方法:
- 引入一个不连续的大气压接口和一个双重压力室.
- 使用不连续的采样来降低操作压力,并容纳更大的入口/滑槽直径.
- 与传统的单,不连续采样接口质谱仪进行比较.
主要成果:
- 与传统仪器相比,检测效率提高了十倍以上.
- 实现了对RISPERIDONE的响应强度的9倍增加,将检测极限降至0.5ppb.
- 精简的电路设计和改进的故障耐受性,没有复杂的时间序列控制.
结论:
- 新型微型质谱仪为实时分析提供了显著的性能增强.
- 设计方便快速检测药物,提高分辨率和降低检测极限.
- 通过使用较小的来减少体积和功耗,可以实现进一步的微型化.
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
730
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
730
Tandem Mass Spectrometry
988
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
988
Mass Analyzers: Overview
665
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
665
Mass Spectrometers
5.4K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.4K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
458
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
458
Mass Analyzers: Common Types
604
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
604