在五天的时间里,腕带的化学吸收
Samantha M Samon1, Kate Hoffman1, Nicholas Herkert1
1Nicholas School of the Environment, Duke University, Durham, NC, USA.
Environmental pollution (Barking, Essex : 1987)
|April 4, 2024
概括
腕带有效地测量化学物质暴露,检测率随着时间的推移而增加. 这项研究证实,穿过的腕带作为可靠的采样器,允许通过部署持续时间进行规范化时获得可比结果.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 毒理学 毒理学 毒理学
背景情况:
- 腕带是评估个人接触化学品的宝贵工具.
- 有限的研究验证了人类佩戴的腕带上的化学积累率.
研究的目的:
- 为了评估5天内人类参与者佩戴的腕带上的113种有机污染物的化学吸收率.
- 为了确定佩戴的腕带是否能作为第一阶级的动态采样器.
主要方法:
- 十名成年参与者每人戴着五条腕带,每天取下一条,持续五天.
- 分析了113种有机污染物的度,包括PCB,OPE,PBDE,甲酸盐,农药和PAH.
- 统计分析估计了化学物质吸收率和与磨损时间的相关性.
主要成果:
- 在只穿了一天的腕带上检测到化学物质.
- 经常检测到的化合物从第三天的20%增加到第四天的34%.
- 在24种化合物中的23种中,在磨损时间和化学度之间发现了显著的线性关联.
结论:
- 穿戴的腕带作为一级动态采样器,类似于实验室PDMS采样器.
- 从不同部署长度的研究中得到的结果,在正常化到磨损时间时是可比的.
- 对于通常检测到的化合物,较短的部署时间可能足够.
更多相关视频
08:02Thin Film Composite Silicon Elastomers for Cell Culture and Skin Applications: Manufacturing and Characterization
Published on: July 3, 2018
10.7K
07:02Stiffness Measurement of Soft Silicone Substrates for Mechanobiology Studies Using a Widefield Fluorescence Microscope
Published on: July 3, 2018
6.9K
相关概念视频
UV–Vis Spectrum
3.1K
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
3.1K
IR Spectrum
3.3K
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
3.3K
NMR Spectroscopy: Chemical Shift Overview
3.6K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
3.6K
UV–Vis Spectroscopy: Woodward–Fieser Rules
30.7K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a...
30.7K
IR Frequency Region: Fingerprint Region
2.1K
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
2.1K
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
3.1K
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
3.1K
