同时逆转颗粒大小分布,热适应系数和火焰中的烟灰聚合物的温度,使用激光诱导的光
Junyou Zhang1, Juqi Zhang2, Xing Huang3
1School of Energy and Environmental Engineering, University of Science and Technology, Beijing 100083, China.
Materials (Basel, Switzerland)
|April 9, 2024
概括
这项研究引入了一种新方法,可以使用激光诱导的发光 (LII) 精确测量烟尘颗粒大小和温度. 该技术通过同时确定多个属性来克服局限性,从而改善火焰内烟灰诊断.
科学领域:
- 燃烧诊断仪器的使用
- 颗粒物分析 颗粒物分析
- 基于激光的测量方法
背景情况:
- 精确测量高温分散颗粒大小和温度对于工业应用至关重要.
- 激光诱导的光 (LII) 是一种强大的非接触式诊断工具,用于在火焰中的烟.
- 现有的LII方法面临挑战,因为预先确定的热特性存在不确定性.
研究的目的:
- 开发一个多参数的反转策略,同时确定烟灰聚合物的特性.
- 通过考虑热性质不确定性来解决传统LII的局限性.
- 为了提高火焰中烟尘特征的准确性和可靠性.
主要方法:
- 实施使用时间解析的LII信号的多参数倒置策略.
- 同时逆转粒子大小分布,热适应系数和初始温度.
- 分析热传输子模型,包括升华和热电辐射,用于LII信号再现.
主要成果:
- 证明了为了准确的LII信号建模,需要包括升华和热电辐射.
- 证实LII颗粒大小对初始颗粒温度偏差敏感.
- 在1100 K和1700 K的同时反转多个烟灰属性时,获得了高精度和信心.
结论:
- 拟议的多参数逆转策略有效地克服了传统LII的局限性.
- 通过同时反转关键参数,可以准确地描述火焰中烟灰聚合物的特征.
- 这种方法为燃烧中的高温粒子诊断提供了更强大的方法.
相关概念视频
Flame Photometry: Overview
573
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
573
Flame Photometry: Lab
244
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
244
Atomic Absorption Spectroscopy: Atomization Methods
418
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
418
Atomic Spectroscopy: Effects of Temperature
330
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
330
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
602
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
602
Atomic Emission Spectroscopy: Interference
183
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
183


