新的简化设计方法,用于工程屏障周围的受污染的网站与考西边界
Liyilan Zhang1, Yiwen Qi1, Yuxin Yuan1
1School of Civil & Environmental Engineering and GeographyScience, Ningbo University, Ningbo, 315211, China.
Scientific reports
|April 10, 2024
概括
简化方法准确地确定泥沟切断壁厚度,以限制污染物. 这些方法提高了受污染地点的设计过程,确保更长的使用寿命和有效的污染物迁移延迟.
科学领域:
- 地质技术工程 地质技术工程
- 环境工程 环境工程
- 水文地质学 水文地质学
背景情况:
- 低透性泥沟切断壁对于减缓污染物迁移至关重要.
- 墙壁厚度是影响这些屏障使用寿命的关键因素.
研究的目的:
- 开发简化方法来确定切断壁的厚度.
- 为污染现场提供准确和高效的设计工具,以持续的污染物流动.
主要方法:
- 进行了理论推导,以建立简化的流量和度极限方法.
- 建议方法的准确性与分析解决方案进行了评估.
主要成果:
- 根据流量和度极限,提出了简化方法来确定切断壁厚度.
- 分析了相对错误,显示了实际设计场景 (C*和F* = 0.1) 的可接受准确性 (最大为4-6%).
- 提出的方法与分析解决方案有很好的一致性.
结论:
- 开发的简化方法有效地提高了切断墙设计的准确性和简单性.
- 这些方法为有效控制受污染地点提供了可靠的基础.
相关概念视频
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
46
Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
46
Design Example: Marking Boundaries of a Site Using a Compass
38
Marking site boundaries using a compass is a precise surveying technique that ensures the accuracy of boundary delineation. The process begins by using provided site details, including the bearings and lengths of each boundary line. The initial step involves calculating latitudes and departures for all sides of the site. This computation verifies that the traverse is free of errors, ensuring a closed and accurate boundary.The process starts at a known point, such as Point A, which is often...
38
Electrostatic Boundary Conditions
473
Consider an external electric field propagating through a homogeneous medium. When the electric field crosses the surface boundary of the medium, it undergoes a discontinuity. The electric field can be resolved into normal and tangential components. The amount by which the field changes at any boundary is given by the difference between the field components above and below the surface boundary.
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
473
Electrostatic Boundary Conditions in Dielectrics
1.2K
When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's...
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's...
1.2K
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
92
Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
92
Boundary Conditions for Current Density
862
Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
862