使用商用数字写字装置内置的三轴加速度计测量心率
Julie Payette1, Fabrice Vaussenat1, Sylvain G Cloutier1
1Department of Electrical Engineering, École de Technologie Supérieure, Montréal, QC H3C 1K3, Canada.
Sensors (Basel, Switzerland)
|April 13, 2024
概括
可穿戴的智能笔可以使用内置的加速度计准确估计心率. 这项技术为健康监测提供了一种非破坏性的方法,与传统的心电图 (ECG) 数据有很好的相关性.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 信号处理 信号处理
背景情况:
- 可穿戴技术通过智能设备提供可访问的健康数据,从而实现持续监控.
- 电心电图 (ECG) 和光电心电图 (PPG) 是对心脏监测的临床标准.
- 可穿戴设备中的加速度计可以估计心率,并过来自运动器件的噪音.
研究的目的:
- 为了比较商业智能笔的加速计与标准心电图读数的心率数据.
- 为了验证智能笔内置传感器对心率估计的准确性.
主要方法:
- 心率数据从STABILO DigiPen.Pen的加速度计中提取出来.
- 从8名志愿者中收集了数据,他们连续写作了5分钟.
- 信号使用巴特沃斯波器进行处理;与参考心电图数据进行比较.
主要成果:
- 智能笔在脉冲间时间 (Δt) 计算中实现了比6.685 × 10-3更好的平均平方误差 (MSE).
- 笔的信号峰值和心电图峰值之间的时间相关性超过了0.99.
- 来自笔的计算心率 (HR) 与参考心电图信号显示了准确的相关性.
结论:
- 通过商业智能笔中的加速度计,可以准确预测心率.
- 这表明了可穿戴传感器技术用于健康监测的新,非侵入性应用.
- 智能笔为可访问和常规的心率跟踪提供了一个有希望的替代方案.
相关概念视频
Equipments Used To Measure Blood Pressure
965
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
965
Pulse rhythm
790
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
790
Special considerations while measuring oxygen saturation
591
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
591
Electrocardiogram
2.3K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.3K
Assessment of blood pressure in brachial artery(one-step method)
585
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
585