嵌入造工艺中的杆的结合分析
Fitsum Haile1, Marco Corradi2, Enea Mustafaraj3
1Department of Mechanical and Construction Engineering, Wynne Jones Building, Northumbria University, Newcastle upon Tyne NE1 8ST, UK.
Materials (Basel, Switzerland)
|April 13, 2024
概括
贴近表面的 (NSM) 杆增强了墙体的强度. 带有优化的砂和结合长度的线条棒在造结构中提供了优越的结合性能和拉出强度.
科学领域:
- 土木工程 土木工程是指土木工程.
- 材料科学 材料科学 材料科学
- 结构工程 结构工程
背景情况:
- 石头结构需要加强抵御曲和剪切力.
- 先进的材料为结构增强提供了新的解决方案.
- 近表面安装 (NSM) 技术,也称为床关节增强,越来越多地被采用.
研究的目的:
- 为了研究石中NSM杆的粘合力学.
- 为了评估杆类型,结合长度和砂对结合性能的影响.
- 为了确定有效的NSM强化体的最佳参数.
主要方法:
- 使用的NSM杆 (光滑和有线) 用于墙体增强.
- 多种结合长度和测试不同的砂类型用于槽填充.
- 进行了拉出测试,以评估结合强度和性能.
主要成果:
- 与光滑棒相比,有线的NSM棒表现出优越的性能.
- 拉出强度受到使用的砂类型的显著影响.
- 优化债券长度和砂选择大大提高了债券表现.
结论:
- NSM杆是增强体强度的一种有前途的技术.
- 螺纹棒在NSM应用中提供更好的粘合性能.
- 仔细选择砂和粘接长度对于最大限度地提高拉出强度和整体效率至关重要.
相关概念视频
Posttensioned Masonry Walls
146
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
146
Mortar Joint Deterioration in Masonry
117
Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
The...
117
Mortar Joints in Brick Masonry
106
Mortar joints play a critical role in brick masonry, filling the spaces between brick to bind them together and provide structural integrity and strength. The thickness of these joints is variable, typically ranging from less than one-fourth inch to over half an inch, based on structural needs and specific applications.
The process of joint tooling is implemented as the mortar begins to harden. This technique involves compacting and shaping the mortar to enhance both the appearance and the...
The process of joint tooling is implemented as the mortar begins to harden. This technique involves compacting and shaping the mortar to enhance both the appearance and the...
106
Torsion of Noncircular Members
135
Circular shafts undergoing torsional stress maintain their cross-sectional integrity due to their axisymmetric nature. This symmetry ensures an even distribution of stress, allowing the shaft to withstand torsion without distorting. In contrast, square bars, lacking this axial symmetry, experience significant distortion across their cross-sections when subjected to torsion, with the exception of along their diagonals and at lines connecting midpoints. A detailed examination of a cubic element...
135
Reinforced Brick Masonry
1.1K
Reinforced brick masonry is an advanced construction technique that enhances the structural integrity of brick walls by incorporating steel reinforcements. These reinforcements are either placed within the hollow cores of bricks or sandwiched between two layers of masonry, known as wythes, and are then secured in place with grout. Grout is a fluid mixture composed of Portland cement, aggregate, and water, providing the necessary bonding agent for the steel and brick.
To fortify brick walls...
To fortify brick walls...
1.1K
Statically Indeterminate Problem Solving
377
Statically indeterminate problems are those where statics alone can not determine the internal forces or reactions. Consider a structure comprising two cylindrical rods made of steel and brass. These rods are joined at point B and restrained by rigid supports at points A and C. Now, the reactions at points A and C and the deflection at point B are to be determined. This rod structure is classified as statically indeterminate as the structure has more supports than are necessary for maintaining...
377