概括
渣的挥发显著影响炼的准确性,特别是在高含氧化物 (PbO) 的情况下. 温度升高和PbO水平加剧了挥发,影响了渣渣的特性,需要对分析仪器进行修改.
科学领域:
- 金工程 金工程 金工程
- 材料科学 材料科学 材料科学
背景情况:
- 含渣的物理性质测试对于炼过程至关重要.
- 渣组件的挥发可能会对测试准确性和工艺控制产生负面影响.
研究的目的:
- 分析不同含有氧化 (PbO) 和氧化 (ZnO) 的渣的挥发特性.
- 了解温度和成分对渣挥发的影响.
主要方法:
- 使用了热重力测量和离子选择性电极飞行时间 (ISP-TOF).
- 通过X射线衍射 (XRD) 和感应合等离子谱 (ICPS) 分析了渣渣的组成和相位.
- 研究了挥发反应机制.
主要成果:
- 在渣中观察到显著的体重减轻,随着PbO含量增加而增加.
- 在900°C以上,挥发主要涉及PbO,在较小程度上涉及ZnO.
- 更高的温度和更长的保留时间导致大量的PbO蒸发.
结论:
- 渣的挥发,特别是PbO,在高温下极大地影响了物理化学性质的测量.
- 分析设备中PbO和ZnO等挥发物质的凝结限制了质谱仪的准确性.
- 分析装置的修改是必要的,以适应渣挥发现象.
更多相关视频
08:35Extending the Lifespan of Soluble Lead Flow Batteries with a Sodium Acetate Additive
Published on: January 7, 2019
9.2K
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
4.5K
相关概念视频
Volatilization
385
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
385
Washing, Drying, and Ignition of Precipitates
911
After filtration, the precipitate is washed to remove coprecipitated impurities and any remaining mother liquor. Colloidal precipitates, such as silver chloride, are washed with an electrolyte (such as dilute nitric acid) to prevent the peptization of the precipitate. In the case of slightly soluble precipitates, the wash solution contains a common ion to reduce solubility. Lead sulfate, which is slightly soluble in water, is washed with dilute sulfuric acid. Similarly, wash solutions may be...
911
Unsoundness of Aggregate due to Volume Change
106
Unsoundness in aggregates due to volume changes is primarily caused by the physical alterations aggregates undergo, such as freezing and thawing, thermal changes, and wetting and drying. Unsound aggregates, when subjected to these changes, result in volume change upon disintegration. This, in turn, contributes to the deterioration of concrete, including scaling, pop-outs, and cracking. Particular types of aggregates, such as porous flints, cherts, and those containing clay minerals, are...
106
Sample Preparation for Analysis: Advanced Techniques
331
Accurate analysis of complex samples often requires advanced preparation techniques to achieve reliable and reproducible results. Samples containing inorganic or organic materials can be challenging to dissolve or decompose effectively. Standard sample preparation methods include acid digestion, fusion, dry ashing, and wet digestion.
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
331
Testing Water Quality
107
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
107
Voltammetry: Stripping Methods
212
Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
212