对于东非电力交易的基础设施充分性
Muhumuza Ezra Rubanda1, Livingstone Senyonga1, Mohammed Ngoma2
1Faculty of Economics, Energy and Management Science, Makerere University Business School (MUBS), Kampala, Uganda.
iScience
|April 16, 2024
概括
东非 东非 非洲 东非
科学领域:
- 能源系统工程 能源系统工程
- 基础设施发展 基础设施发展
- 国际贸易 国际贸易 国际贸易
背景情况:
- 综合能源市场需要强大的电力供应基础设施.
- 东非共同体 (EAC) 的目标是建立一个整合的电力市场.
- 追踪基础设施发展的进展对于市场整合至关重要.
研究的目的:
- 评估发电和输电基础设施是否足以促进东非综合电力市场的电力交易.
- 评估基础设施发展的进展与"总体规划2013-2023"中设定的目标相比.
主要方法:
- 获得价值分析 (EVA) 用于比较计划的基础设施目标与到2022年实际交付.
- 利用了2013-2023年总体规划和2022年实际基础设施数据的数据.
- 分析重点关注发电能力和输电网络扩建.
主要成果:
- 到2022年,计划的12,567MW发电容量的54%已经实现,而输电网络目标在211%的完成率超出预期.
- 基础设施发展的投资流入明显高于预期 (325%的差异).
- 获得价值的余相当于3.57亿美元,这表明尽管贸易活动比预期慢,但仍有贸易潜力.
结论:
- 虽然发电能力仍在发展,但输电基础设施已经先进,为电力交易创造了余容量.
- 建议进行代规划,以同步发电和输电基础设施的发展,以提高贸易效率.
- 调查结果表明,在EAC地区,基础设施建设和市场运营之间需要进行战略调整.
相关概念视频
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Power System Distribution
238
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
238
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Primary Distribution
102
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
102
Transformers in Distribution System
102
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
102
Maximum Power Flow and Line Loadability
107
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107