在两个角膜拓仪和光谱域光学连贯性断层扫描仪之间,撕裂半月体高度一致性和可重现性
Ivo Soares1, Eva Ramalho1, Francisco Miguel Brardo1
1Department of Physics, University of Beira Interior, Covilhã, Portugal.
Clinical & experimental optometry
|April 16, 2024
概括
使用Oculus Keratograph 5M,Medmont Meridia和Spectralis SD-OCT进行的撕裂阴茎高度 (TMH) 测量显示了良好的观察者间可靠性和可重复性. 虽然设备是相关的,但它们在临床干眼诊断中是不可互换的.
科学领域:
- 眼科医生 眼科 眼科
- 医疗成像医学成像
- 干眼疾病研究 干眼疾病研究
背景情况:
- 撕裂阴囊高度 (TMH) 是诊断和管理干眼疾病的关键指标.
- 准确和可重复的TMH测量对于有效的临床评估至关重要.
- 评估用于TMH测量的不同设备对于标准化临床实践至关重要.
研究的目的:
- 评估三种设备TMH测量的可复制性和一致性:Oculus Keratograph 5M,Medmont Meridia和Spectralis SD-OCT. 这三种设备的重复性和一致性.
- 在非临床参与者中比较TMH测量的观察者间和设备间可靠性.
主要方法:
- 一项涉及56名参与者的横截面研究.
- 使用Oculus Keratograph 5M,Medmont Meridia和Spectralis SD-OCT进行序列和随机图像采集.
- 统计分析包括重复测量 ANOVA 和 Bland-Altman 情节来评估一致性和可靠性.
主要成果:
- 所有设备都表现出良好的观察者间可靠性 (ICC ≥0.877) 和可重复性 (CV ≤16.53%).
- 设备间的可靠性是中等的 (ICC = 0.621).
- 与Oculus Keratograph 5M和Medmont Meridia (p=0.02) 不同的是,Spectralis SD-OCT和Oculus Keratograph 5M在TMH测量中没有显著差异 (p=0.19).
结论:
- 眼镜光仪5M,Medmont Meridia和Spectralis SD-OCT提供了可靠的观察者间TMH测量.
- 设备间的可靠性是中等的,Spectralis SD-OCT和Oculus Keratograph 5M显示出密切的相关性.
- 虽然可以重复,但Oculus Keratograph 5M和Medmont Meridia对于临床TMH测量是不可互换的.
相关概念视频
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Overview of Microscopy Techniques
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...