在COVID-19大流行期间加拿大电力市场:初步评估
Andrew Leach1, Nic Rivers2, Blake Shaffer3
1Alberta School of Business, University of Alberta, Edmonton, Alberta.
概括
由于COVID-19大流行,加拿大安大略省和阿尔伯塔省等省份的电力需求减少. 这项研究强调了对电力市场的影响,并建议将这些数据用作经济指标.
科学领域:
- 经济学 经济学 经济学
- 能源政策 能源政策
- 环境科学 环境科学
背景情况:
- COVID-19大流行严重扰乱了全球经济和能源市场.
- 了解大流行对电力需求和供应的影响对于市场稳定和政策至关重要.
- 加拿大电力市场经历了独特的影响,由于不同的省级法规和能源来源.
研究的目的:
- 分析COVID-19大流行对加拿大选定的省份电力需求和供应的影响.
- 调查对电力市场运作和政策的影响.
- 评估使用电力数据作为实时经济指标的潜力.
主要方法:
- 利用加拿大各省的高频电力数据.
- 分析了整个安大略省,阿尔伯塔省,不列颠哥伦比亚省和新不伦瑞克省的电力需求变化.
- 检查了发电源和电力净出口的变化.
主要成果:
- 在安大略省,电力需求下降了约10%,在阿尔伯塔省,不列颠哥伦比亚省和新不伦瑞克省下降了5%.
- 阿尔伯塔省观察到天然气工厂产量减少,油砂产量增加.
- 安大略省经历了电力净出口的增长.
结论:
- 疫情造成了加拿大电力市场的显著转变,影响了需求和供应动态.
- 潜在的政策影响包括对电价的影响以及实时电力数据对经济监测的价值.
- 需要在加拿大所有省份提高电力数据的可访问性,以便更好地分析和响应.
相关概念视频
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Power System Three-Phase Short Circuits
83
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
83
Primary Distribution
102
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
102
Electrical Energy
1.2K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.2K
Fast Decoupled and DC Powerflow
191
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
191