环境电离和微型质谱仪的便携式仪器仪表
Barry L Smith1, Thomas Hankinson1, Simon Maher1
1Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, United Kingdom;
Annual review of analytical chemistry (Palo Alto, Calif.)
|April 19, 2024
概括
本综述对便携式质谱仪 (pMS) 和环境电离技术进行了批判性评估. 我们制定了评估pMS可移植性的标准,并讨论了该领域最近的进展和未来的趋势.
科学领域:
- 分析化学 分析化学
- 仪器科学 仪器科学
背景情况:
- 便携式质谱 (pMS) 是一个快速发展的领域.
- 评估pMS仪器的可移植性涉及设计,部署和操作的主观考虑.
研究的目的:
- 批判性地评估便携式质谱仪 (pMS) 的现状.
- 定义评估pMS和环境电离源可移植性的标准.
- 审查最近关于环境电离和微型质谱仪器便携式仪器仪表方面的进展的文献.
主要方法:
- 关于最近在便携式质谱和环境电离方面的进展的文献综述.
- 制定一套评估pMS可移植性的标准.
- 分析流行和重要的便携式质谱仪和环境电离仪器仪表.
主要成果:
- 该审查确立了评估pMS可移植性的明确标准.
- 突出了环境电离和微型质谱仪的便携式仪器仪表方面的重大进展.
- 确定了该领域的新兴趋势和未来前景.
结论:
- 需要一种标准化的方法来评估pMS可移植性.
- 便携式质谱学领域有望实现显著的增长和创新.
- 提供了关于pMS未来研究和开发的建议.
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
728
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
728
Mass Spectrometers
5.4K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.4K
Atomic Emission Spectroscopy: Instrumentation
379
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
379
Mass Analyzers: Common Types
604
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
604
Tandem Mass Spectrometry
988
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
988
Mass Analyzers: Overview
663
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
663