双向长短期记忆在分离NO和SO2紫外差分吸收频谱信号中的应用
Bo Peng1, Zhen Tang1, Shiji Xian1
1Liangjiang School of Artificial Intelligence, Chongqing University of Technology, China.
概括
精确监测工业氧化 (NO) 和二氧化硫 (SO2) 排放对于环境保护至关重要. 这项研究引入了一种先进的UV-DOAS系统,使用Bi-LSTM算法进行精确的超低度检测.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 光学工程是指光学工程.
背景情况:
- 工业化石燃料的燃烧释放出有害的氧化 (NO) 和二氧化硫 (SO2).
- 精确测量这些污染物的超低度是技术上具有挑战性的.
- 现有的方法在SO2和NO之间的交叉干扰方面扎.
研究的目的:
- 开发一种新的光学测量系统,用于精确检测超低度的SO2和NO.
- 为了克服SO2和NO在混合气体样本中的相互干扰的挑战.
- 建立可靠的工业排放环境监测方法.
主要方法:
- 在200-230nm范围内利用紫外差光学吸收光谱学 (UV-DOAS).
- 开发了一种双向长短期记忆 (Bi-LSTM) 算法,以提取差异光密度并减轻干扰.
- 采用非线性校准模型来实现精确的气体度逆转.
主要成果:
- 对SO2的检测极限 (DL) 为0.27ppm,全尺度误差为3.15%.
- 对NO的DL达到0.32ppm,全尺度误差为2.81%.
- 计算的低不确定性:SO2的1.73%和NO检测的1.96%.
结论:
- 开发的UV-DOAS系统有效地测量了超低的SO2和NO度.
- Bi-LSTM算法成功地解决了SO2-NO干扰,提高了测量准确度.
- 这种方法为工业污染物的环境监测提供了一个有希望的解决方案.
相关概念视频
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
2.6K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
2.6K
¹³C NMR: ¹H–¹³C Decoupling
1.1K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K
UV–Vis Spectroscopy: Molecular Electronic Transitions
1.4K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.4K
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
883
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
883
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.0K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K