使用低成本样本进行XRF校准和实施,以量化口红中的无机元素
M Pilakouta1, M Trapali1, N Kallithrakas-Kontos2
1University of West Attica, Department of Biomedical Sciences, Campus 1, Ag. Spyridonos 28, Egaleo 12243 Athens, Greece.
MethodsX
|April 23, 2024
概括
本研究提出了一种低成本的方法,用于校准能量分散式X射线光 (XRF) 系统,使用学生准备的样本. 这种方法作为实践实验室活动,用于教学XRF校准和元素分析.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
- 教育方法 教育方法
背景情况:
- 校准对于准确的光谱分析至关重要.
- 能量分散式X射线光 (XRF) 是一种强大的元素分析技术.
- 开发具有成本效益的校准方法对于可访问性至关重要.
研究的目的:
- 为XRF校准提供一种低成本的样本准备方法.
- 为XRF系统校准设计一个本科/研究生实验室活动.
- 探索XRF的应用,以确定学生相关样本中的元素度.
主要方法:
- 准备廉价的校准样本.
- 使用能量分散的X射线光 (XRF) 光谱学.
- 实施程序作为学生实践实验室练习.
主要成果:
- 成功准备了适合XRF校准的低成本样本.
- 证明了该程序作为教育工具的可行性.
- 展示了在选定的样本中确定元素度的方法.
结论:
- 拟议的方法为XRF校准提供了负担得起和有效的方法.
- 这项实验室活动增强了学生对光谱校准和元素分析的理解.
- 在实践中,XRF可以用于分析学生感兴趣的样本中的元素.
相关概念视频
Atomic Emission Spectroscopy: Overview
2.1K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.1K
Atomic Absorption Spectroscopy: Lab
349
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
349
Atomic Emission Spectroscopy: Lab
161
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
161


