推动同位素信封:当载体通道污染它们邻居的信号时
Connor Peterson1, Hannah Boekweg1, Eilenora Presley1
1Biology Department, Brigham Young University, Provo UT 84604.
bioRxiv : the preprint server for biology
|April 25, 2024
概括
单细胞蛋白质组学中的试剂杂质在使用载体通道时可能导致不准确的量化. 限制载体数量对于可靠的单细胞蛋白质组分析至关重要.
科学领域:
- 生物化学 生物化学
- 分析化学 分析化学
- 细胞生物学 细胞生物学
背景情况:
- 单细胞蛋白质组学旨在量化单个细胞的蛋白质组,这对于了解健康和疾病至关重要.
- 使用异标签的多重复合技术可以改善的识别,但可能会影响定量准确性.
- 含有许多细胞的载体通道用于提高单细胞蛋白质组学中的识别率.
结论:
- 必须尽量减少载体通道的贡献,以确保准确的单细胞蛋白质组量化.
- 为了优化方法,平衡标识率与定量准确度至关重要.
- 对于可靠的单细胞蛋白质组研究,建议仔细控制载体通道量.
相关概念视频
¹³C NMR: ¹H–¹³C Decoupling
1.1K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
451
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
451
Interference: Path Lengths
1.3K
Consider two sources of sound, that may or may not be in phase, emitting waves at a single frequency, and consider the frequencies to be the same.
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
1.3K
Mass Spectrometry: Isotope Effect
2.0K
Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the difference between the molecular mass. Furthermore, the intensity of these signals is dependent on the...
2.0K
Atomic Absorption Spectroscopy: Interference
745
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
745
Aliasing
133
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
133


