研究在低温下混凝土的机械性能
Xiangyi Li1, Lihui Qin1, Lina Guo1
1School of Water Resources and Civil Engineering, Northeast Agricultural University, Harbin 150030, China.
Materials (Basel, Switzerland)
|April 27, 2024
概括
这是混凝土混凝土.
科学领域:
- 材料科学 材料科学 材料科学
- 土木工程 土木工程是指土木工程.
- 建筑工程工程 建筑工程
背景情况:
- 寒冷地区的建筑业正在增加.
- 了解在低温下混凝土的性能对于结构完整性至关重要.
- 在全球范围内,混凝土是必不可少的建筑材料.
研究的目的:
- 在各种低温下研究混凝土的机械性能.
- 在零度以下条件下分析不同混凝土等级的强度变化.
- 提供用于寒冷地区建筑材料选择的数据.
主要方法:
- 在混凝土样本上进行了单轴压缩测试.
- 在包括20°C,0°C,-20°C,-30°C和-40°C在内的温度下进行了测试.
- 分析了结果,以确定强度,弹性模量和峰值应变变化.
主要成果:
- 压力强度最初从20°C降低到0°C,然后随着温度进一步下降而增加.
- 弹性模块随着温度的下降而持续增加.
- 峰值应变最初增加 (20°C到0°C),然后在较低的温度下降.
- 立方多项式拟合描述了上升的曲线段,参数在较低的温度下降.
结论:
- 在低温下,混凝土的机械行为发生显著变化.
- 在零度以下的温度下,强度和刚度通常会提高,但峰值应变会减少.
- 这些发现对于在寒冷气候下设计耐用结构至关重要.
更多相关视频
相关概念视频
Cold Weather Concreting
70
When freshly poured concrete is exposed to freezing temperatures before it has set, the water within the concrete can freeze. This expansion disrupts the setting process, delays chemical reactions necessary for hardening, and increases the volume of pores within the hardened concrete, which weakens its overall structure. If the concrete manages to reach an appreciable strength before it freezes, the damage can be somewhat mitigated.
To counteract the negative impacts of cold weather, ensuring...
To counteract the negative impacts of cold weather, ensuring...
70
Mass Concreting
62
Mass concreting refers to the process of placing large volumes of concrete, such as in gravity dams. The heat generated during the cement hydration process and differential cooling rates within the concrete mass can lead to a temperature gradient, which can result in thermal cracks in the concrete mass.
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
62
Frost Resistant Concrete
77
Concrete's susceptibility to frost damage during freeze-thaw cycles demands strategic measures to enhance its frost resistance. Employing techniques like air entrainment, adjusting the water-cement ratio, proper curing, and selecting appropriate aggregates are essential.
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
77
Hot Weather Concreting
64
Concreting at elevated temperatures accelerates the hydration process, leading to quicker setting but potentially reducing the long-term strength of the concrete structure. Additionally, low air humidity fosters rapid moisture loss from the concrete, resulting in reduced workability, pronounced plastic shrinkage, and a higher likelihood of crazing.
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
64
Frost Action on Concrete
97
Concrete structures in cold climates, such as those along roadsides, can retain moisture. This moisture makes them susceptible to frost-related damage when temperatures fall below freezing. Adding moisture worsens the damage during temperature fluctuations, leading to repeated freezing and thawing. De-icing salts, spread over these structures to melt ice, add to the freeze-thaw cycle, and draw even more moisture into the concrete.
This freeze-thaw cycle primarily causes surface scaling, where...
This freeze-thaw cycle primarily causes surface scaling, where...
97
Masonry in Cold and Hot Weather Conditions
84
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
84