使用差压传感器和Arduino微控制器进行流入水深传感器建设的低成本方法
Reagan H Pearce1, Michael A Chadwick2, Bruce Main3
1Department of Geography, Faculty of Social and Historical Sciences, University College London, Gower Street, London WC1E 6BT, UK.
Sensors (Basel, Switzerland)
|April 27, 2024
概括
一个新的,低成本的基于Arduino的水深传感器为水文监测提供了一个预算友好的替代方案. 这种DIY传感器为洪水风险和水资源管理提供了准确的数据,为研究人员证明了成本效益.
科学领域:
- 水文学 水文学
- 环境监测 环境监测
- 传感器技术 传感器技术
背景情况:
- 准确的水文数据对于有效的洪水风险和水资源管理至关重要,特别是在气候变化的影响下.
- 高分辨率的监控网络往往受到高成本和环境挑战的阻碍.
- 开发负担得起的监测解决方案对于广泛收集水文数据至关重要.
研究的目的:
- 设计和测试一个低成本的"自制"水深传感器.
- 评估这个传感器对未来水文监测项目的可行性.
- 将性能和成本效益与商用级传感器进行比较.
主要方法:
- 使用Arduino微控制器,差压传感器,热敏电阻,实时时钟和SD卡模块构建了一个传感器.
- 部署了基于Arduino的日志记录器,并与校准的Solinst LevelLogger 5 Junior一起部署了六个月.
- 收集和分析了来自英国维西河的水深和温度数据.
主要成果:
- 基于Arduino的记录器显示,水深的平均绝对误差为±0.69厘米,水温为±0.415°C.
- 这种DIY传感器的成本为133.35英 (168.26美元),远低于商业采伐机的408英 (514.83美元).
- 低成本的传感器为水文数据收集提供了相当大的经济优势.
结论:
- 基于Arduino的水深传感器是一种可行的,具有成本效益的水文监测工具.
- 它的低成本使得它对预算有限的项目非常有利.
- 项目的适用性取决于在时间投资和准确性方面接受潜在的权衡.
相关概念视频
Measurement of Fluid Pressure
195
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
195
Equipments Used To Measure Blood Pressure
964
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
964