易于使用的基于MOX的VOC传感器,用于高效的室内空气质量监测
Radu Nicolae Pietraru1, Maximilian Nicolae1, Ștefan Mocanu1
1Faculty of Automatic Control and Computers, National University of Science and Technology Politehnica Bucharest, 060042 București, Romania.
Sensors (Basel, Switzerland)
|April 27, 2024
概括
基于金属氧化物半导体 (MOX) 的传感器为监测室内空气质量 (IAQ) 提供了一个用户友好的解决方案. 本案例研究强调了它们的易于安装和实时的VOC数据,以有效管理IAQ.
科学领域:
- 环境科学 环境科学
- 传感器技术 传感器技术
- 分析化学 分析化学
背景情况:
- 室内空气质量 (IAQ) 对健康和生产力至关重要.
- 挥发性有机化合物 (VOC) 是常见的室内空气污染物.
- 现有的IAQ监测可能是复杂和昂贵的.
研究的目的:
- 评估基于金属氧化物半导体 (MOX) 的传感器用于IAQ监测的实际应用和好处.
- 在实验室环境中展示MOX传感器的易用性和集成性.
- 评估MOX传感器用于实时检测VOC/TVOC的可行性.
主要方法:
- 采用了一个案例研究方法.
- 测量是在大学实验室进行的.
- 基于MOX的VOC/TVOC传感器被集成到IAQ监测系统中.
主要成果:
- 基于MOX的传感器展示了简单的集成和用户友好的操作.
- 获得了关于VOC度的精确实时数据.
- 传感器显示安装方便,维护要求最低.
结论:
- 基于MOX的传感器为IAQ管理提供了实用和有效的解决方案.
- 它们的用户友好型功能有助于在各种环境中广泛采用.
- 这项技术为高效和可访问的IAQ监控提供了一个有希望的途径.
相关概念视频
Measurement of Air Content in Concrete
137
Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
The pressure method,...
137
Pulse Oximetry
328
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
328
Electronic Distance Measuring Instruments
35
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
35
Assessment of Ventilation I: Respiratory Rate
1.1K
Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
1.1K
Respiratory Assessment: Purpose and Indications
1.1K
Respiratory assessment is a cornerstone of nursing assessments, crucial for the early detection of patient deterioration. This evaluation transcends routine procedures, representing a critical skill nurses must master to ensure optimal patient care.
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
1.1K
Temperature Measurement Sites
1.7K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.7K