基于IDDA的SF6HVCB运行状态评估方法
Tong Bai1, Chenhao Sun1, Wenqing Feng2
1School of Electrical & Information Engineering, Changsha University of Science & Technology, Changsha 410004, China.
Sensors (Basel, Switzerland)
|April 27, 2024
概括
本研究提出了一种综合数据驱动分析 (IDDA) 模型,用于评估SF6高压断路器 (HVCB) 的运行状态. 该模型通过准确评估HVCB状态和优先考虑组件维修来改进维护策略.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 资产管理资产管理.
背景情况:
- 精确评估SF6高压断路器 (HVCB) 运行状态对于可靠的电网运行至关重要.
- 现有的HVCB评估方法可能缺乏精度,影响维护战略的有效性.
- 开发先进的分析模型是必要的,以优化HVCB的性能和寿命.
研究的目的:
- 引入一个综合数据驱动分析 (IDDA) 模型,用于精确评估SF6HVCBs的运行状态.
- 建立一个强大的框架,为SF6HVCBs制定明智的维护策略.
- 量化各种HVCBs运行指标的意义.
主要方法:
- 开发用于SF6HVCB运行状态评估的综合数据驱动分析 (IDDA) 模型.
- 引入相对降解重量 (RDW) 度量来量化指标的意义.
- 制定一个关键因素稳定性 (CFS) 模型用于定量环境指标分析.
- 设计一个优化的模糊推理 (OFI) 系统,以增强连续指标的处理.
主要成果:
- 与现有方法相比,拟议的IDDA模型在评估SF6HVCB运行状态时表现出更高的准确性.
- RDW指标有效量化了不同运营指标的相对重要性.
- CFS模型提供了对影响HVCB性能的环境因素的定量见解.
- 该OFI系统提高了处理连续运营数据的效率.
结论:
- 开发的IDDA模型提供了一个非常准确的方法来评估SF6HVCB的运行条件.
- 该模型为各种HVCB组件的维护序列的优先级提供了可靠的基础.
- 这种方法支持优化资产管理,提高高压电力基础设施的可靠性.
相关概念视频
Circuit Breaker and Fuse Selection
102
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
102
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Three-Phase Short Circuit—Unloaded Synchronous Machine
141
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
141
Differential Relays
131
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
131
Power System Three-Phase Short Circuits
83
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
83
Directional Relays
107
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
107