使用Surgivisio系统导航脚螺丝插入:错位率和风险因素 - 大约648个螺丝
Maxime Saad1, Jérôme Tonetti2, Gaël Kerschbaumer1
1Service de chirurgie orthopédique et traumatologique, hôpital Nord, CHU de Grenoble, boulevard de la Chantourne, 38700 La Tronche, France; Université Grenoble-Alpes, Grenoble, France.
Orthopaedics & traumatology, surgery & research : OTSR
|April 27, 2024
概括
Surgivisio导航系统显示了92.4%的令人满意的脚螺丝植入率. 女性性别,胸脊水平高于D10和开放手术增加了错位风险.
科学领域:
- 脊柱外科手术 脊柱外科手术
- 医疗导航技术 医疗导航技术
- 外科手术的结果
背景情况:
- 脚螺丝的错位是脊柱外科手术中的一个重要问题.
- 各种技术旨在减少脚螺丝错位的发生率.
- Surgivisio导航系统是用于提高准确度的技术之一.
研究的目的:
- 通过Surgivisio导航系统评估脚螺丝错位率.
- 为了识别与螺丝错位相关的风险因素.
- 评估对操作时间和辐射暴露的影响.
主要方法:
- 一个单一的回顾性连续病例系列进行了.
- 分析了使用Surgivisio系统进行脚螺丝植入的97名患者.
- 通过术后CT扫描来评估螺丝位置,并使用单变量和多变量方法分析风险因素.
主要成果:
- 在648个螺丝上,获得了92.4%的令人满意的螺丝植入率.
- 每个螺丝的平均操作时间为14.5±6.7分钟,有效剂量为每个螺丝0.47±0.31mSv.
- 女性性别,D10以上的植入和开放手术被确定为错位的重要风险因素.
结论:
- Surgivisio导航系统展示了与现有文献相比的脚螺丝错位率和操作时间.
- 术内患者参考位移被假设为导航系统故障的潜在原因.
相关概念视频
Angle of Twist - Elastic Range
Consider a cylindrical shaft with a length denoted by L and a consistent cross-sectional radius referred to as r. This shaft undergoes a torque at the free end. The highest shearing strain within the shaft is directly proportional to the twist angle and the radial distance from the shaft axis. When the shaft behaves elastically, this shearing strain can be articulated using variables such as the applied torque, radial distance, the polar moment of inertia, and the modulus of rigidity. By...
Transmission Shafts: Problem Solving
Designing a solid shaft that transmits power from a motor to a machine tool involves a series of calculations to ensure the shaft can withstand the stresses applied by bending moments and torques. First, calculate the torque exerted on the gear, considering the power transmitted by the shaft and its rotational speed. Following this, compute the tangential forces acting on the gears, which directly relate to the torque and the gear radius.
Next, use bending moment diagrams for the shaft to...
Next, use bending moment diagrams for the shaft to...
Errors in Taping
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
Adjusting a Traverse
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
Errors in Global Positioning System
Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...