实时成像和大量填充和常规树脂复合材料内部空隙形成的定量分析:一个OCT评估
Xinyu Yang1, Yuhao Yang1, Yingji Li2
1Department of Cariology & Endodontics, The Affiliated Stomatological Hospital, Jiangxi Medical College, Nanchang University, Nanchang 330006, Jiangxi, China; Jiangxi Province Key Laboratory of Oral Biomedicine, Nanchang 330006, Jiangxi, China.
Photodiagnosis and photodynamic therapy
|April 27, 2024
概括
光学连贯断层扫描 (OCT) 能够有效地检测牙科复合材料中的微泄漏. 与传统树脂相比,散装树脂,特别是 Surefil SDR Flow +,在热循环后的空隙形成较少.
科学领域:
- 牙科材料科学 牙科材料科学
- 生物材料研究 生物材料研究
- 恢复性牙科 恢复性牙科
背景情况:
- 在牙科修复中评估微泄漏对于长寿至关重要.
- 现有的微泄漏评估方法存在局限性.
- 光学连贯性断层扫描 (OCT) 提供实时的定量差距分析.
研究的目的:
- 用OCT量化分析大量填充和常规树脂复合材料的内部空隙形成.
- 为了比较不同类型的树脂复合材料的实时差距形成和微漏漏易感性.
- 评估热循环对各种牙科修复材料中缺口形成的影响.
主要方法:
- 在50个提取的牙中,使用常规 (Filtek Z350 XT) 或散装填充树脂 (X-tra fil,Filtek散装填充后部修复剂,Surefil SDR Flow +,Filtek流动修复剂) 修复了I类腔.
- 在光固化过程中进行了实时OCT成像,随后进行了固化后扫描,以测量初始差距百分比 (G1 %).
- 样品经历了5000次热循环 (5°C-55°C),随后进行了OCT扫描,以确定循环后差距百分比 (G2%) 和差距百分比变化 (ΔG%).
主要成果:
- 两组之间没有观察到初始差距形成 (G1%) 的显著差异.
- 在热循环后,常规树脂 (Filtek Z350 XT) 显示最高的G2%,而Surefil SDR Flow +显示最低.
- Surefil SDR Flow + 在热循环后,间隙百分比 (ΔG%) 的变化最小,表明优越的边际完整性.
结论:
- 光学连贯断层扫描 (OCT) 是在牙科修复中实时检测微泄漏的宝贵工具.
- 热循环显著影响传统树脂复合材料,导致间隙形成的增加.
- 苏瑞菲尔SDR Flow + (散装树脂) 在初始和老化后都显示出有前途的耐微泄漏性.
相关概念视频
Computed Tomography
7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Imaging Studies for Cardiovascular System V: CT
671
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
671
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
973
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
973
Imaging Studies III: Computed Tomography
893
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
893