低强度脉冲超声波:具有免疫调节和抗炎潜力的物理刺激
Wenxin Liang1,2, Beibei Liang1, Kaicheng Yan1
1Center of Medicine Clinical Research, Department of Pharmacy, Medical Supplies Center of Chinese PLA General Hospital, 28 Fu Xing Road, Beijing, 100853, People's Republic of China.
Annals of biomedical engineering
|April 29, 2024
概括
低强度脉冲超声波 (LIPUS) 通过调节免疫反应,促进愈合并减少炎症. 需要进一步的研究才能充分理解它的抗炎机制和治疗潜力.
科学领域:
- 生物医学工程 生物医学工程
- 再生医学是一种再生医学.
- 物理疗法物理治疗
背景情况:
- 治疗性超声波,特别是低强度脉冲超声波 (LIPUS),以其在愈合和减少炎症方面的作用而闻名.
- 利普斯通过降低促炎细胞因子,加速免疫细胞回归和促进组织修复来表现出抗炎作用.
研究的目的:
- 为了探索LIPUS的抗炎和免疫调节机制.
- 调查LIPUS作为一种非侵入性物理治疗炎症状况的潜力.
主要方法:
- 检查LIPUS对炎症的影响的体外和体内研究的综述.
- 对涉及LIPUS介导抗炎反应的信号通路的分析.
主要成果:
- 利普斯通过影响关键信号通路来影响炎症.
- 可能会激活诸如integrin/FAK/PI3K/Akt和VEGF/eNOS之类的通路.
- 包括TLRs/NF-κB和p38-MAPK在内的途径的潜在抑制.
结论:
- 利普斯表现出显著的抗炎和免疫调节特性.
- 利普斯抗炎作用的精确机制涉及复杂的信号通路.
- 利普斯是一种有前途的非侵入性治疗方式,需要进一步研究.
相关概念视频
Pulse amplitude and quality
3.6K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
3.6K
Muscle Stimulation Frequency
4.7K
The contraction strength of muscles is regulated by motor neurons, which modulate the frequency of action potentials dispatched to the motor units based on the body's requirements. This process of varying the muscle stimulation frequency allows muscles to contract with a force that is precisely tailored to the needs of the moment, whether lifting a feather or a heavy box.
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
4.7K
Heart Sounds
3.7K
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
3.7K
Acute Inflammation II: Local and Systemic Effects
56
Acute inflammation produces a coordinated set of local and systemic changes that limit injury, eliminate pathogens, and initiate repair. These responses arise within minutes of infection, trauma, or chemical insult and are driven by vascular alterations and leukocyte-derived mediators. When the stimulus resolves, the reaction typically abates within days.Local EffectsAt the site of injury, arteriolar vasodilation increases blood flow, resulting in redness and warmth. Simultaneously, increased...
56