左捆分支节奏设置以超过心脏再同步治疗的双心室节奏?
1Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana 141001, India. akashbatta02@gmail.com.
World journal of cardiology
|May 1, 2024
概括
左捆支部区域节奏 (LBBP) 在心力衰竭患者中显示为心脏再同步治疗 (CRT) 的前景,可能超过双心室节奏 (BiVP). 需要进行更大规模的试验来确认LBBP-CRT.
科学领域:
- 心脏病学 心脏病学
- 电子生理学 电子生理学
- 心脏衰竭管理的管理
背景情况:
- 长期的右心室节奏可以导致心肌病,推动寻找像双心室节奏 (BiVP) 这样的替代方案.
- BiVP通过重新同步机电失调来有效治疗心力衰竭,但具有显著的非响应率 (20-30%).
- 没有对BiVP的反应通常是由于非生理左心室刺激,绕过自然导电系统.
更多相关视频
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
524
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
14.7K
相关概念视频
Electrophysiology of Normal Cardiac Rhythm
3.8K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
3.8K
Heart Failure Drugs: Inotropic Agents
574
Positive inotropic agents are commonly used as the first line of treatment for heart failure. One such agent is digoxin, derived from the genus Digitalis, which has been known for centuries but effectively utilized since 1785. However, these cardiac glycosides can have potentially toxic effects due to their mechanism of action, which involves inhibiting Na+/K+-ATPase and increasing contractility. Digoxin is absorbed orally and distributed in various tissues, including the CNS. It has a long...
574
Cardiac Action Potential
1.4K
Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
1.4K
Imbalances in Cardiac Output
1.4K
The heart's primary function is to pump blood throughout the body, maintaining a balance between blood sent out (cardiac output) and blood returning (venous return). If this balance is disrupted, it can result in congestive heart failure (CHF), a severe condition where the heart becomes an inefficient pump, leading to inadequate blood circulation.
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
1.4K
The Cardiac Cycle
87.8K
The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
87.8K
Conduction System of the Heart
6.3K
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
6.3K
