监测静脉循环:新的技术和应用
August A Longino1, Katharine C Martin2, Ivor S Douglas3
1Department of Internal Medicine, University of Colorado Hospital.
Current opinion in critical care
|May 1, 2024
概括
静脉压升高有助于患者的疾病. 静脉过量超声波 (VExUS) 评分提供了一种新的床边方法,使用多普勒超声波来评估静脉压力,在早期研究中显示出有希望.
科学领域:
- 关键护理医学 关键护理医学
- 心血管生理学心血管生理学
- 诊断性超声波的使用
背景情况:
- 静脉压升高是一个重要的,但往往被忽视的,导致患者发病的原因.
- 目前用于评估静脉压力的方法,如体检和右心导管 (RHC),在临床实践中存在局限性.
- 评估中枢静脉压力 (CVP) 对于管理严重病患者的流体状况和心功能至关重要.
研究的目的:
- 审查静脉压测量的临床意义.
- 讨论静脉压力评估的现有技术.
- 引入静脉过量超声波 (VExUS) 评分作为一种新的,非侵入性的床边方法.
主要方法:
- 审查有关静脉压测量技术的现有文献.
- 介绍VExUS评分,一种将下腔静脉 (IVC) 直径与肝,门,静脉多普勒超声评估相结合的方法.
- VExUS评分与RHC测量和临床结果的相关性.
主要成果:
- 维克苏斯评分与RHC测量有很强的相关性.
- 维克苏斯评分与心急性损伤,尿液反应和流体状况的改善有关.
- 目前对非心脏病患者群体的研究是有限的,异质的和不确定的.
结论:
- 维克苏斯评分 (VExUS Score) 显示,它是一个新的床边静脉压评估工具.
- 需要进一步的研究来验证VExUS评分在不同的患者群体和临床环境.
- 对静脉堵塞的多普勒超声波评估需要进一步调查临床实用性.
相关概念视频
Assessment of the Cardiovascular System III: Palpation
321
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
321
Venous Return
4.1K
The circulatory system plays a crucial role in ensuring the optimal functioning of the human body. One of its critical components is venous return - the process that completes the blood circulation cycle. This article will delve into the concept of venous return, how it works, and its significance to our health.
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
4.1K
Equipments Used To Measure Blood Pressure
964
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
964
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K