在一般病房的可穿戴无线连续生命体征监测
Jobbe Pl Leenen1,2, Lisette Schoonhoven3,4, Gijs A Patijn1,5
1Connected Care Centre, Isala, Zwolle.
Current opinion in critical care
|May 1, 2024
概括
使用可穿戴传感器的持续生命体征监测 (CVSM) 显示出在一般病房中早期检测患者恶化的前景. 然而,目前在准确性,可用性和整合方面的挑战限制了已证明的临床结果的改善.
科学领域:
- 生物医学工程 生物医学工程
- 临床信息学 临床信息学
- 患者监测 患者监测
背景情况:
- 连续生命体征监测 (CVSM) 的可穿戴无线传感器为一般病房的早期患者恶化检测提供了潜力.
- 审查侧重于可穿戴CVSM系统的技术进步,用户观点和患者结果的影响.
研究的目的:
- 对一般病房的可穿戴CVSM系统的最新证据进行审查.
- 突出技术特征,用户观点和患者结果的影响.
主要方法:
- 对可穿戴CVSM的最新证据进行系统审查.
- 技术特征,可用性和临床影响的分析.
主要成果:
- 传感器的准确性各不相同,特别是在门诊患者中; 缺乏验证协议.
- 护士和患者的可用性至关重要;需要与医院IT和工作流程自动化集成.
- 观察到的ICU入院和快速反应小组呼叫的减少缺乏强大的统计学意义.
结论:
- 在一般病房可能会广泛实施CVSM.
- 尽管有理论上的好处,但已证明的临床效果是混合的,在数据质量,可用性和集成方面存在挑战.
- 需要强有力的证据来支持CVSM对患者结果,工作流程和成本效益的影响.
相关概念视频
Pulse rhythm
787
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
787
Guidelines For Measuring Vital Signs
1.6K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
1.6K
Introduction to Vital Signs
2.1K
Vital signs are physiological measurements that help key into the status of the body's essential functions. These include body temperature, pulse rate, respiratory rate, and blood pressure, commonly abbreviated as T, P, R, and BP. Some healthcare settings also consider oxygen saturation (SpO2) and, in specific contexts, pain and level of consciousness as additional vital signs.
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
2.1K
Pulse Oximetry
328
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
328
Equipments Used To Measure Blood Pressure
964
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
964
Errors occurring during blood pressure monitoring
715
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
715