钻井校准的精度用于动态导航
Mohammed Y Al-Jarsha1, Ashraf F Ayoub2, Mohammed M Almgran2
1Department of Oral Surgery, School of Medicine, Dentistry and Nursing, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom; Department of Oral and Maxillofacial Surgery, College of Dentistry, University of Baghdad, Baghdad, Iraq.
Journal of dentistry
|May 4, 2024
概括
钻孔校准用于动态导航牙植入物放置显示出良好的可重复性,但可以受到钻孔长度和灵活性的影响. 临床医生必须意识到潜在的错误,特别是在更长或更灵活的演练中,以确保准确性.
科学领域:
- 牙科植入物学 牙科植入物学
- 手术导航 手术导航
- 医疗器械校准 医疗器械校准
背景情况:
- 动态导航系统可以提高牙植入物放置的准确性.
- 钻井校准是这些程序中的关键步骤.
- 了解影响校准可重现性的因素对于改善结果至关重要.
研究的目的:
- 在动态导航中量化钻井校准过程的可重现性.
- 为了确定影响校准精度的人为因素.
- 为了提高整体牙植入物放置的准确性.
主要方法:
- 六个钻头和四个植入物被三个操作员使用NaviDent®系统校准.
- 通过测量从计划植入点的尖端位置偏差来评估可复制性.
- 在考虑钻孔长度和形状的情况下,评估了内部和操作者之间的可靠性.
主要成果:
- 实现了令人满意的分类器间可重现性,尖端位置的变化范围从0.3到3.7毫米.
- 较长的钻孔往往会提高校准精度.
- 在使用非锁定适配器和灵活的长尖钻机的长腿部植入物时,校准错误增加了.
结论:
- 临床医生必须认识到,在牙和牙植入物的动态导航中,钻孔校准错误是固有的.
- 考虑钻孔长度,灵活性和适配器类型至关重要.
- 在校准和校准后准确性检查期间手动稳定对于最小化错误至关重要.
相关概念视频
Adjusting a Traverse
56
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
56
Common Leveling Mistakes and Errors
71
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
71
Distance Corrections
28
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
28
Types of Global Positioning System Surveys
55
GPS surveying methods vary in application, accuracy, and data collection techniques, catering to diverse surveying and mapping needs. Static GPS, kinematic GPS, and real-time kinematic (RTK) surveying are widely used. Each technique offers distinct advantages.Static GPS involves placing one receiver at a known reference point and another at the target point. It collects exact positional data by observing multiple satellite ranges over an extended period, achieving centimeter-level accuracy for...
55
Errors in Global Positioning System
44
Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...
44
Differential Leveling
170
Differential leveling is a precise method in surveying used to determine the elevation difference between two points. Its primary goal is to establish accurate vertical measurements to create level surfaces or grade lines critical for designing and constructing infrastructures such as roads, bridges, and buildings.The procedure for differential leveling begins with setting up and leveling the instrument at a point where the benchmark can be seen. The level rod is held on the benchmark (BM), and...
170