使用定制压力传感器系统测量非营养吸入参数
Ross M Westemeyer1, Alaina Martens1, Hannah Phillips1
1Department of Communication Sciences and Disorders, Northeastern University.
Journal of visualized experiments : JoVE
|May 6, 2024
概括
非营养吸 (NNS) 装置准确地测量婴儿吸行为. 这种定量NNS评估作为预测未来发育和识别风险婴儿早期干预的生物标志物.
科学领域:
- 发育儿科 发育儿科
- 神经科学是一个神经科学.
- 生物医学工程 生物医学工程
背景情况:
- 婴儿的非营养吸 (NNS) 行为是发展的关键指标.
- 量化NNS为婴儿健康和潜在的发育轨迹提供了宝贵的见解.
- 现有的NNS评估方法缺乏准确性和用户友好性.
研究的目的:
- 引入和验证一种新的,可携带的压力传感器系统,用于量化婴儿NNS行为.
- 确定NNS参数 (持续时间,振幅,频率) 作为可靠的发育结果的生物标志物.
- 探索NNS评估在各种研究领域的实用性,包括食干预,人口研究和环境健康.
主要方法:
- 开发一种易于使用,可携带的压力传感器系统,用于记录 NNS 在软奶上.
- 分析NNS信号以获得爆发持续时间 (s),振幅 (cmH2O) 和频率 (Hz) 的定量测量.
- 在各种研究环境中应用NNS设备,包括干预研究,发育特征和神经发育相关性.
主要成果:
- 该NNS设备成功地用准确性和可靠性量化了NNS关键参数.
- NNS特征与养干预,人口特异性发展和神经发育结果相关.
- 该设备已被用于研究子宫内暴露对婴儿NNS发育的影响.
结论:
- 使用开发的设备进行定量NNS评估,可以作为一个有价值的生物标志物,用于预测食,言语语言,认知和运动发展.
- 该NNS设备有助于识别患有发育迟缓风险的婴儿.
- 根据NNS参数与神经发育结果的相关性,可以快速实施早期干预.
相关概念视频
Measurement of Fluid Pressure
195
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
195
Pipe Flowrate Measurement
685
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
685
Equipments Used To Measure Blood Pressure
964
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
964