相关实验视频
Updated: Jun 27, 2025

06:34
The Caco-2 Cell Bioassay for Measurement of Food Iron Bioavailability
Published on: April 28, 2022
4.7K
低甲氧-铁 (III) 复合物的物理化学,结构和功能特性及其对患有缺铁性贫血的老鼠的影响
Jing Jing1, Zhijun Zhang2, Zhiyong Hu2
1School of Chemistry and Chemical Engineering, North University of China, Taiyuan 030051, China; Department of Chemistry and Chemical Engineering, Taiyuan Institute of Technology, Taiyuan 030008, China.
概括
一种新型的低甲烯 (LMP) - 铁 (III) 复合物显示出对治疗缺铁性贫血 (IDA) 的希望. 这种铁补充剂有效地改善了IDA大鼠模型中的关键健康指标.
科学领域:
- 营养生物化学 营养生物化学
- 材料科学 材料科学 材料科学
- 药理学 药理学是指药理学的学科.
背景情况:
- 缺铁性贫血 (IDA) 是一种普遍存在的全球营养障碍.
- 开发有效和生物可利用的铁补充剂对于公共健康至关重要.
研究的目的:
- 合成和表征一个低甲烯 (LMP) - 铁 (III) 复合体.
- 在IAD的老鼠模型中评估这种新型复合物的治疗疗效.
主要方法:
- 使用HPSEC,HPIC,CV,FTIR,1H NMR,XRD,SEM和CD进行物理化学和结构性表征.
- 对IDA大鼠的治疗效果的评估,监测体重,血红蛋白,血清铁和自由红细胞原.
主要成果:
- 与LMP相比,LMP-铁 (III) 复合体呈现出增加的分子量和改善的结晶性.
- 在LMP的-OH/-COOH组和Fe3+之间的协调形成了β-FeOOH.
- 在IDA大鼠中,LMP-铁 (III) 显著改善了体重,血红蛋白和血清铁水平,同时降低了自由红细胞原.
结论:
- 合成的LMP-铁 (III) 综合体在临床前小鼠模型中显示出治疗缺铁性贫血的显著治疗潜力.
- 这项研究为开发基于pectin-metal复合物的新铁补充剂提供了基础.
相关概念视频
Colors and Magnetism
11.6K
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
11.6K
EDTA: Chemistry and Properties
1.9K
Polydentate ligands are most widely used in complexometric titrations because they form more stable complexes with the metal ions than mono- or bidentate ligands due to the chelate effect. Examples of polydentate ligands are ethylenediaminetetraacetic acid (EDTA), crown ethers, and cryptands. The most important feature of optimal polydentate ligands is the ability to form 1:1 complexes in a single-step process. Amino carboxylic acid derivatives are frequently used as complexing agents. EDTA is...
1.9K
EDTA: Auxiliary Complexing Reagents
580
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
580
Complexometric Titration: Ligands
946
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
946
Extraction: Advanced Methods
446
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
446
Effects of EDTA on End-Point Detection Methods
272
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
272