我们未来区域电力系统的愿景:四个欧盟国家的公民偏好
Franziska Mey1, Johan Lilliestam2, Ingo Wolf1
1Energy Transitions & Public Policy Group, Research Institute for Sustainability (RIFS) - Helmholtz Centre Potsdam, Potsdam, Germany.
iScience
|May 8, 2024
概括
公民对可再生电力系统的偏好显示出对区域解决方案的强烈愿望. 最受欢迎的设计优先考虑屋顶太阳能,社区所有权,避免新的输电基础设施,平衡社会和技术需求.
科学领域:
- 能源政策和社会科学 社会科学
- 可再生能源系统的整合可再生能源系统的整合
- 公众论与环境规划
背景情况:
- 全球气候目标需要向可再生电力系统过渡.
- 关于发电和基础设施部署的公众反对和冲突阻碍了可再生能源的转型.
- 公民对可再生能源期货的偏好仍未得到充分研究,特别是在系统设计权衡方面.
研究的目的:
- 调查四个欧洲国家对可再生电力系统设计的公民偏好.
- 通过探索细微的权衡和上下文化的偏好,超越传统调查.
- 将社会考虑与可再生能源规划的技术经济建模相结合.
主要方法:
- 联合分析调查对丹麦,葡萄牙,波兰和德国的4103名个人进行.
- 探索区域电力系统设计的权衡和上下文偏好.
- 识别最少和最喜欢的系统配置.
主要成果:
- 在所有被调查国家中,最受青的可再生电力系统设计主要是区域性的.
- 首选系统的关键特征包括依赖屋顶太阳能和公共所有权模式.
- 首选的系统不需要大幅扩建输电基础设施.
结论:
- 公民偏好强烈支持去中心化,以区域为重点的可再生能源系统.
- 基于社区的可再生能源项目,特别是屋顶太阳能,是非常理想的.
- 将公共偏好纳入能源系统设计可以克服部署障碍,并促进可再生能源的过渡.
更多相关视频
相关概念视频
Three-Phase Circuits
405
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
405
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Maximum Power Flow and Line Loadability
107
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107
Load-frequency control
158
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
158
Primary Distribution
102
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
102