在环境空气中膨胀的微波阿贡等离子体射流的超谱成像
Fatima Khazem1, Antoine Durocher-Jean1, Ahmad Hamdan1
1Département de Physique, Université de Montréal, Montréal, Québec H3C 3J7, Canada.
The Review of scientific instruments
|May 8, 2024
概括
这项研究引入了一个超光谱成像系统,用于高效地,空间分辨率诊断大气压等离子体喷射. 该技术提供了关键等离子体参数的详细地图,改进了微波等离子体分析.
科学领域:
- 等离子体物理学的物理学
- 频谱学是一种光谱学.
- 光学成像技术的成像
背景情况:
- 在大气压下非平衡等离子体通常使用光学发射光谱学进行分析.
- 有效地确定空间分辨的等离子体特性仍然是一个重大挑战.
研究的目的:
- 开发和验证一种超光谱成像系统,用于微波阿贡等离子体喷射的详细空间分析.
- 通过使用先进的光学诊断来有效地绘制关键等离子体参数.
主要方法:
- 使用了一种超光谱成像系统,配备可调节的布拉格格成像仪和科学CMOS摄像机.
- 在广泛的波长范围内记录空间分辨率的光学发射图像.
- 应用后处理技术,包括阿贝尔变换,用于2D辐射分辨率映射.
主要成果:
- 产生了前所未有的和氧线强度的空间地图.
- 量化Ar的变态稳定数密度和的激发温度.
- 在合理的时间框架内证明有效的数据采集和分析.
结论:
- 基于Bragg-grating的高光谱成像是一种有利的技术,用于微波等离子体喷射诊断.
- 开发的系统提供了基本等离子体参数的详细地图.
- 这种方法增强了用于各种应用的微波等离子喷射的分析.
相关概念视频
Atomic Emission Spectroscopy: Overview
2.1K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
596
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
596
Atomic Emission Spectroscopy: Lab
161
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
161
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
722
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
722
Atomic Emission Spectroscopy: Instrumentation
378
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
378
Atomic Emission Spectroscopy: Interference
182
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
182