旋转变压器和UNET架构用于纠正磁共振图像重建中的运动工件
Md Biddut Hossain1, Rupali Kiran Shinde1, Shariar Md Imtiaz1
1Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea.
International journal of biomedical imaging
|May 10, 2024
概括
这项研究介绍了MACS-Net,这是一种使用Swin变压器来纠正MRI扫描中的运动文物的深度学习方法. 新方法显著改善图像质量,加速数据采集,性能优于现有方法.
科学领域:
- 医疗成像医学成像
- 人工智能的人工智能
- 生物医学工程 生物医学工程
背景情况:
- 运动文物是磁共振成像 (MRI) 中的一个重大挑战,导致图像退化和延长扫描时间.
- 现有的运动校正技术往往难以处理复杂的运动模式,或需要额外的硬件.
研究的目的:
- 开发和评估一种基于深度学习的新方法,用于纠正MRI中的运动文物.
- 为了加速MRI数据采集和重建,同时保持高图像保真度.
主要方法:
- 开发了Swin网络 (MACS-Net) 的运动器件校正,在Unet架构中使用Swin变压器层.
- 采用了带有转移窗口的等级变压器来进行多尺度特征提取,以及用于增强分辨率的双重上采样技术.
- 在原始MRI数据集上训练并测试模型,该数据集包含各种运动工件和相应的地面真实图像.
主要成果:
- 与六种最先进的方法相比,MACS-Net显著减少了规范化根平均平方误差 (NRMSE),增加了结构相似度指数 (SSIM) 和改善了峰值信号噪声比 (PSNR).
- 对于短暂的运动 (<5秒),NRMSE从45.25%降至17.51%,SSIM从79.43%增加到91.72%,PSNR从18.24升至26.57dB.
- 对于延长运动 (5-10s),NRMSE从60.30%降至21.04%,SSIM从33.86%提高到90.33%,PSNR从15.64增加到24.99dB.
结论:
- MACS-Net有效地纠正MRI中的运动工件,从而大幅改善图像质量指标.
- 该方法显示了加速MRI采集和重建的潜力,而不会损害解剖细节.
- 深度学习方法显示出卓越的性能,特别是在处理简短和延长的运动场景时.
相关概念视频
Magnetic Resonance Imaging
5.1K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.1K
NMR Spectrometers: Resolution and Error Correction
686
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
686
Atomic Nuclei: Magnetic Resonance
647
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
647
Imaging Studies I: CT and MRI
235
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
235