概括
在传输电子显微镜 (TEM) 中倾斜骨段不会显著改变矿物板表面厚度测量. 精确的骨头超结构分析可以在没有切口倾斜的情况下实现,简化了TEM程序.
科学领域:
- 材料科学 材料科学 材料科学
- 生物矿物化 生物矿物化
- 电子显微镜电子显微镜
背景情况:
- 骨超结构分析依赖于传输电子显微镜 (TEM).
- 骨矿物质包括多晶板 (厚度为3-6纳米).
- 矿物板的表面厚度可能随着TEM的截面方向而变化.
研究的目的:
- 调查切口倾斜是否影响骨矿物质板块的表面厚度.
- 为了确定是否需要倾斜来准确的基于TEM的骨矿物质厚度测量.
主要方法:
- 通过离子束磨削制备的皮层人类骨段.
- 在TEM明亮场和HAADF成像中,截面倾斜 (±20°).
- 在各种倾斜角度测量明显的矿物质血小板厚度.
主要成果:
- 表面厚度是±20°倾斜的两倍.
- 最小的表面厚度 (真实厚度) 通过沿板的方向倾斜而发现.
- 矿石板变得越来越少解决超过20°倾斜.
- 类似的平均厚度,从黑色板块图像中获得.
结论:
- 对于精确的骨矿物质板厚度测量,截面倾斜是不必要的.
- 简化的TEM协议可以用于骨超结构分析.
更多相关视频
09:13Characterization of Ultra-fine Grained and Nanocrystalline Materials Using Transmission Kikuchi Diffraction
Published on: April 1, 2017
13.6K
07:00Preparing Lamellae from Vitreous Biological Samples Using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography
Published on: August 5, 2021
3.3K
相关概念视频
Transmission Electron Microscopy
5.5K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.5K
Overview of Electron Microscopy
9.0K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
9.0K