[角膜曲率和外围厚度对度计读数的影响]
A A Antonov1, A V Volzhanin1, E A Klinicheva1
1Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Vestnik oftalmologii
|May 13, 2024
概括
角膜的生物力学特性,特别是角膜歇斯底里和角膜阻力因子,显著影响平面化测音仪的准确性. 外周角膜厚度和曲率对度计读数的影响较小.
科学领域:
- 眼科医生 眼科 眼科
- 生物医学工程 生物医学工程
- 视光学测量 视光学测量 视光学测量
更多相关视频
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
197
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
287
相关概念视频
Focusing of Light in the Eye
2.7K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
2.7K
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
92
During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance.
92
Special considerations while measuring blood pressure
721
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
721