家庭用电器的过渡数据集具有强烈的切换事件
Dongyang Zhang1,2, Xiaohu Zhang1, Lei Hua1
1Department of Computer Science North China Electric Power University (Baoding), BaoDing, China.
Scientific data
|May 14, 2024
概括
研究人员开发了用于非侵入性负载监控 (NILM) 的具有密集切换事件 (TDHA) 的家用电器过渡数据集. 这一数据集有助于提高与中国相似的电力使用模式的地区的设备识别精度.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 数据科学数据科学数据科学
背景情况:
- 非侵入性负载监控 (NILM) 使用深度学习 (DL) 进行设备识别和能源分析.
- 由于电力环境的变化,NILM研究需要广泛的,特定于区域的数据集.
- 现有的数据集可能无法完全捕捉到不同区域电力消费模式的细微差别.
研究的目的:
- 介绍家用电器与强度切换事件 (TDHA) 数据集的短暂数据集.
- 为中国和类似地区的NILM研究提供高质量的开放数据集.
- 提高NILM算法的性能和适用性.
主要方法:
- 从10种常见的家用电器收集了瞬间开关数据.
- 确保高采样率和准确标记器件事件.
- 使用精确的继电器控制来切换设备,以最大限度地减少机械干扰.
主要成果:
- TDHA数据集提供了现实的设备启动波形.
- 具有精确的标签和高采样率,用于详细分析.
- 通过使用可控继电器开关来减轻干扰.
结论:
- 该TDHA数据集支持NILM算法的进步.
- 在NILM系统中提高了设备识别准确度.
- 允许在具有与中国相似的电力特征的地区更广泛地应用NILM.
相关概念视频
Transient and Steady-state Response
176
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
176
Electrical Energy
1.2K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.2K
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Heating and Cooling Curves
22.8K
When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
22.8K
Household Wiring And Electrical Safety
1.2K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.2K
Series R—L Circuit Transients
97
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
97