使用ICP-OES确定在伊朗消费的造茶的元素度:风险评估研究
Yeganeh Mazaheri1, Nabi Shariatifar2,3, Shahrokh Nazmara1
1Department of Environmental Health, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Biological trace element research
|May 15, 2024
概括
茶饮不构成重大健康风险,因为包括,和在内的微量金属含量仍低于安全限值. 在某些茶类型和包装中发现和的度更高,造时间增加增加了金属的溶解度.
科学领域:
- 食品化学 食品化学
- 环境健康 环境健康
- 分析化学 分析化学
背景情况:
- 茶是一种全球消费的饮料,含有杂质的潜在健康风险.
- 茶中的微量元素和重金属需要对消费者安全进行仔细评估.
研究的目的:
- 在各种茶中量化16种微量元素.
- 评估与茶饮食相关的潜在人类健康风险.
- 为了比较伊朗和进口茶样之间的金属度.
主要方法:
- 感应合等离子光学发射光谱仪 (ICP-OES) 用于微量元素分析.
- 使用蒙特卡洛模拟的健康风险评估.
- 主要组件分析 (PCA) 用于金属类型的相关性.
主要成果:
- (Mn) 在黑茶和绿茶中平均度最高.
- (B) 在Stachys lavandulifolia中度最高.
- 茶包显示的和 (Al) 度高于未包装的茶.
- (Pb), (Hg) 和 (Cd) 的含量低于已确定的安全限值.
- 伊朗的茶样通常含有比进口茶样更高的金属度.
- 增加造时间 (10分钟) 提高了,,,铁和等元素的可溶性.
结论:
- 在典型的造条件下,茶的消费没有显著的非致癌性健康风险.
- 包装类型和造时间可以影响造茶中的微量元素含量.
- 对特定茶叶品种和来源进行进一步的研究是有必要的.
相关概念视频
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
596
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
596
Atomic Absorption Spectroscopy: Lab
348
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
348
Atomic Emission Spectroscopy: Lab
161
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
161
Precipitation and Co-precipitation
1.8K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.8K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
449
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
449