基于米网络的分销网络的故障语义网络中的知识实体的智能故障检测策略
Xinjie Sun1, Tao Qin1, Lingyun Tong1
1State Grid Nanjing Power Supply Company, Nanjing, China.
PloS one
|May 16, 2024
概括
本研究引入了一种新方法,用于检测智能电网语义网络中的故障,使用状态空间方程和米网络. 该方法通过识别知识实体变量异常来提高分销网络运营的可靠性.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 人工智能的人工智能
背景情况:
- 智能电网技术使分布网络的复杂语义网络模型成为可能.
- 这些模型的知识实体中的缺陷可能会导致验证失败和操作问题.
研究的目的:
- 为智能电网语义网络中的知识实体变量开发一种新的故障检测方法.
- 提高配送网络的可靠性和运营完整性.
主要方法:
- 构建一个状态空间方程来建模知识实体在故障期间的变量行为.
- 应用未知输入观察者策略来检测异常.
- 利用一个马网络来提高故障识别准确度.
主要成果:
- 拟议的方法有效地检测知识实体变量中的异常.
- 模拟证实了故障检测方法的有效性.
- 西安网络增强了错误状态的差异化.
结论:
- 开发的故障检测方法对于智能电网中的语义网络是有效的.
- 这项研究有助于提高配电网络运营的稳定性.
- 状态空间方程和米网络的集成为智能电网故障管理提供了一个有前途的解决方案.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
07:15Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
6.8K
相关概念视频
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Fault Types
84
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
84
Power System Three-Phase Short Circuits
83
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
83
Bus Impedance Matrix
119
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
119
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Zones of Protection
166
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
166