Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

109.9K
Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
109.9K
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

160
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
160
Electrodes: Overview01:17

Electrodes: Overview

1.7K
 Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
1.7K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

564
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
564
Electrochemical Gradient and Channel Proteins: An Overview01:21

Electrochemical Gradient and Channel Proteins: An Overview

2.1K
An electrochemical gradient is a fundamental concept in biology and chemistry. It regulates the movement of ions across cell membranes. This movement is influenced by two factors:
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell.  This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
2.1K
Electrogravimetric Analysis: Overview01:30

Electrogravimetric Analysis: Overview

220
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
220

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Biomass-Derived Hydrogels for Load-Bearing Connective Tissue Repair: Integrative Reinforcement, Bio-Functional Design, and Emerging Pathways Toward Clinical Translation.

Advanced healthcare materials·2026
Same author

Machine learning-assisted kinetic matching model for rational electrode design in aqueous zinc-ion batteries.

Nature communications·2025
Same author

Microphase-Separated Hydrogel Electrolytes with Selective Ion Transportation Pathways for Flexible Zinc-Ion Batteries.

Advanced materials (Deerfield Beach, Fla.)·2025
Same author

Thermochromic Smart Windows with Ultra-High Solar Modulation and Ultra-Fast Responsive Speed Based on Solid-Liquid Switchable Hydrogels.

Research (Washington, D.C.)·2025
Same author

Electrolyte Evolution for Flexible Energy Storage Systems: From Liquid to Solid, from Rigid to Soft, and from Organic to Aqueous.

Chemical reviews·2025
Same author

Dynamic volume compensation realizing Ah-level all-solid-state silicon-sulfur batteries.

Nature communications·2025

相关实验视频

Updated: Jun 25, 2025

Development of Efficient OLEDs from Solution Deposition
07:09

Development of Efficient OLEDs from Solution Deposition

Published on: November 4, 2022

2.1K

基于共享电极设计的潜在梯度驱动双功能电色和电化学装置.

Gang Xu1, Wei Zhang1, Guangjun Zhu1,2

  • 1Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing, 211189, China.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)
|May 21, 2024
PubMed
概括

一种新型的自动供电电色装置集成了一个Zn/MnO2电池与普鲁士蓝色,用于封闭系统操作. 这种可穿戴技术在没有外部电源的情况下提供快速,持久的颜色变化,为先进的电子显示器铺平了道路.

关键词:
电染色装置是一种电染色装置.梯度潜力的梯度潜力是什么自动驱动的自动驱动汽车分享的电极是共享的.离子电池是一种离子电池.

更多相关视频

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
07:51

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection

Published on: February 1, 2022

3.2K
An Electrochemical Cholesteric Liquid Crystalline Device for Quick and Low-Voltage Color Modulation
10:33

An Electrochemical Cholesteric Liquid Crystalline Device for Quick and Low-Voltage Color Modulation

Published on: February 27, 2019

8.4K

相关实验视频

Last Updated: Jun 25, 2025

Development of Efficient OLEDs from Solution Deposition
07:09

Development of Efficient OLEDs from Solution Deposition

Published on: November 4, 2022

2.1K
Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
07:51

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection

Published on: February 1, 2022

3.2K
An Electrochemical Cholesteric Liquid Crystalline Device for Quick and Low-Voltage Color Modulation
10:33

An Electrochemical Cholesteric Liquid Crystalline Device for Quick and Low-Voltage Color Modulation

Published on: February 27, 2019

8.4K

科学领域:

  • 材料科学 材料科学 材料科学
  • 电化学 电化学 电化学
  • 可穿戴电子产品的电子产品

背景情况:

  • 自动供电的电色设备通常需要开放的系统来补充氧化剂,限制它们与可穿戴电子产品的整合.
  • 开发封闭系统的电色设备对于可穿戴技术的实际应用至关重要.

研究的目的:

  • 通过将Zn/MnO2离子电池与普鲁士蓝色 (PB) 电色系统集成,开发具有封闭配置的自动供电电色装置.
  • 研究电色性能和灵活可穿戴应用的潜力.

主要方法:

  • 集成Zn/MnO2电池与普鲁士蓝色电色系统,使用双共享电极 (Zn和MnO2).
  • 电极充当阳极,将PB减少为普鲁士白 (PW),而MnO2电极充当阴极,氧化PW.
  • 制造和测试一个标准的和一个空气处理的ZnIdexIdexIdexMnO2设备.

主要成果:

  • 采用的ZnBodyRadioMnO2系统实现了卓越的光学对比度 (80.6%) 和快速切换速度 (2.0/3.2秒用于漂白/染色).
  • 空气处理装置显示了70.3%的光学对比度,快速切换 (2.2/4.8秒) 和超过80个循环.
  • 封闭的配置允许制造灵活的电色装置.

结论:

  • 集成的Zn/MnO2电池和PB电色系统为自动供电,封闭系统的电色设备提供了可行的解决方案.
  • 开发的系统表现出高性能,耐用性和灵活性,适合下一代可穿戴电子产品.
  • 这种方法克服了开放系统的局限性,使可穿戴设备中的实际自动供电变色功能成为可能.