使用剪切探头测量消散率的ATOMIX基准数据集.
Ilker Fer1, Marcus Dengler2, Peter Holtermann3
1Geophysical Institute, University of Bergen, Bergen, Norway. ilker.fer@uib.no.
Scientific data
|May 21, 2024
概括
本研究提供了基准数据集,用于测量水中环境中的流动力动能消耗 (ε). 这些经过验证的数据集,使用剪切探头,帮助研究人员标准化流测量和提高数据质量.
科学领域:
- 海洋学和石灰岩科学
- 流体动力学 流体动力学
- 环境科学 环境科学
背景情况:
- 在水生系统中,流混合对于传输热量,营养物质和动量至关重要.
- 流量以流动力动能消耗率的单位质量 (ε) 来量化.
- 带有剪切探头的微结构造型仪通常用于 ε 测量.
研究的目的:
- 编制和验证五个基准数据集的集合,用于 ε 测量.
- 为非专家使用剪切探头数据的从业人员提供最佳实践指南.
- 为更广泛的科学用途标准化流数据处理和存档.
主要方法:
- 使用微结构造型仪与剪切探针进行流测量.
- 从各种仪器和环境条件中编制的数据集.
- 根据海洋学研究科学委员会 (SCOR) 工作组ATOMIX的建议处理数据.
主要成果:
- 这里介绍了一组经过验证的,针对 ε 测量的五个基准数据集.
- 数据集涵盖了广泛的环境条件和仪器类型.
- 数据集根据已建立的最佳实践进行处理.
结论:
- 基准数据集将指导用户测试和验证他们的 ε 估计方法.
- 数据处理和质量保证的标准化将提高流研究的可靠性.
- 这些资源促进了关键的海洋流数据的存档和可访问性.
相关概念视频
Extraction: Partition and Distribution Coefficients
The distribution law or Nernst's distribution law is the law that governs the distribution of a solute between two immiscible solvents. This law, also known as the partition law, states that if a solute is added to the mixture of two immiscible solvents at a constant temperature, the solute is distributed between the two solvents in such a way that the ratio of solute concentrations in the solvents remains constant at equilibrium.
For extracting a solute from an aqueous phase into an organic...
For extracting a solute from an aqueous phase into an organic...
Trimmed Mean
While measuring the mean of a data set, care needs to be taken when associating the mean to its central tendency. The same goes for the arithmetic mean, the geometric mean, or the harmonic mean. This is because the presence of a single outlier data value can significantly affect the mean. That is, the mean is sensitive to fluctuations in the data set.
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...