重新考虑 photoplethysmogram 在自由生活环境中的信号质量评估
Yan-Wei Su1, Chia-Cheng Hao2, Gi-Ren Liu3,4
1Department of Applied Mathematics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
Physiological measurement
|May 22, 2024
概括
一个新的适应性非波模型 (ANHM) 提供了一种系统的方法来评估信号质量. 这种方法超越了视觉检查,在现实环境中改进了生物医学信号处理.
科学领域:
- 生物医学工程 生物医学工程
- 信号处理 信号处理
- 生理学 生理学 生理学
背景情况:
- 评估生物医学信号质量至关重要,但缺乏精确的模型,特别是在自由生活条件下.
- 目前用于光聚体质谱 (PPG) 信号质量评估的方法往往是主观和不足的.
- 缺乏可靠的质量评估模型阻碍了可靠的生物医学信号处理.
研究的目的:
- 提出一种新的数学模型来评估PPG信号质量.
- 通过信号分解来探索PPG信号的结构性质.
- 倡导对生物医学应用中的信号质量进行修订理解.
主要方法:
- 使用自适应非和模型 (ANHM) 建模PPG信号.
- 应用分解算法来分析PPG信号结构.
- 利用在自由生活环境中记录的真实世界数据进行验证.
主要成果:
- 证明了在PPG分析中需要重新考虑信号质量的概念.
- 突出了信号质量和信号分解技术之间的联系.
- 展示了专家标记的高质量的PPG信号用于心率推导的潜在问题.
结论:
- 除了视觉检查之外,还需要一种新的,系统的PPG信号质量评估方法.
- 拟议的ANHM模型显示出开发一种基于分解的质量评估系统的前景.
- 先进的信号处理工具与ANHM相结合,可以提高PPG衍生指标的可靠性.
更多相关视频
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
398
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
19.9K
相关概念视频
Pulse amplitude and quality
1.7K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
1.7K
Equipments Used To Measure Blood Pressure
962
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
962
Special considerations while measuring pulse
578
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
578
Pulse rhythm
785
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
785
Pulse
501
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
501
Special considerations while measuring blood pressure
719
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
719