物理和水质参数对水分网残留衰变的影响
Julius Caesar Kwio-Tamale1, Charles Onyutha1
1Department of Civil and Environmental Engineering, Kyambogo University, P.O. Box 1 Kyambogo, Kampala, Uganda.
Heliyon
|May 23, 2024
概括
最初的度和电导率显著影响饮用水配电系统中的衰变. 对于保持安全的残留水平,水质参数比物理因素更为重要.
科学领域:
- 环境科学 环境科学
- 水处理工程水处理工程
- 公共卫生 公共卫生
背景情况:
- 是全球饮用水的主要消毒剂.
- 世界卫生组织 (WHO) 的指导方针建议剩余含量在0.2-5.0 mg/l之间.
- 了解影响分解的因素对于确保水安全至关重要.
研究的目的:
- 分析物理和水质参数对饮用水分配系统中分解的影响.
- 确定预测从处理厂到消费点的损失的关键参数.
主要方法:
- 利用主要组件分析 (PCA),定向树分析和回归模型.
- 研究了各种参数对整个配送网络中水平的影响.
主要成果:
- 最初的,电导率和距离共同解释了62%的衰变.
- 最初的度 (特征重要性0.47) 和电导率 (0.23) 是最重要的因素.
- 物理参数 (距离,管径,流速,压力,运行时间) 的综合重要性低于单独的初始.
结论:
- 传统的化主要去除无机反应物,使有机反应物成为主要的二次污染物.
- 水质参数在预测衰变方面比物理参数更有影响力.
- 供水公司管理人员应优先监测水质参数,以保持安全的残留水平.
相关概念视频
Quality of Water
92
In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
92
Testing Water Quality
106
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
106
Factors Affecting Solubility
33.4K
Compared with pure water, the solubility of an ionic compound is less in aqueous solutions containing a common ion (one also produced by dissolution of the ionic compound). This is an example of a phenomenon known as the common ion effect, which is a consequence of the law of mass action that may be explained using Le Chȃtelier’s principle. Consider the dissolution of silver iodide:
33.4K
Design Example: Designing a Residential Plumbing System
675
The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
675
Effect of Sea Water on Concrete
214
Concrete exposed to seawater can undergo degradation like the dissolution of ettringite and gypsum, increasing the material's porosity and decreasing its strength. In contrast, the crystallization of salts within the concrete's pores can cause expansion, particularly above the waterline where evaporation occurs. Nonetheless, this expansion only happens when seawater, enabled by the concrete's permeability, manages to infiltrate the structure.
Concrete in areas between tide marks,...
Concrete in areas between tide marks,...
214
Plasticizers
75
Water-reducers, or plasticizers, are chemical admixtures used in concrete to improve strength and workability. These additives reduce the water-cement ratio without compromising workability, lower the cement content while maintaining the same workability, or increase workability to assist concrete placement in inaccessible areas.
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
75