概括
甲基二硫氧化物 (DMSO) 显著影响细胞培养中的硫代谢,即使在接受的水平. 这些复杂的效应干扰研究,需要在生物学研究中仔细考虑.
科学领域:
- 生物化学 生物化学
- 细胞生物学 细胞生物学
- 代谢学 代谢学 代谢学
背景情况:
- 硫酸二甲基 (DMSO) 是生物研究中常见的有机硫溶剂,广泛用于细胞培养和体内研究.
- 它对硫代谢参数的潜在干扰经常被忽视.
- 粘多糖症研究通常涉及改变硫代谢的细胞系.
研究的目的:
- 研究DMSO对细胞培养中的硫代谢参数的影响.
- 为了确定DMSO干扰是否可以通过将其封装在聚合体中来减轻.
主要方法:
- 利用了三个细胞系,包括Caco-2和两个粘多糖的模型.
- 在DMSO添加到培养基后评估硫代谢参数.
- 进行了用DMSO封装在聚合体 (PEG-PLGA) 中的实验,以评估细胞膜效应的缓解.
主要成果:
- 即使在普遍接受的度下,添加DMSO也会改变硫代谢的关键参数.
- 观察到复杂的协同效应,而不仅仅是简单的添加干扰.
- 将DMSO部分加载到聚合体中显示出减轻某些破坏性影响的潜力.
结论:
- 在专注于硫代谢的研究中,DMSO是干扰的重要来源.
- DMSO的影响很复杂,不能总是通过减去对照值来纠正.
- 研究人员必须考虑DMSO对硫代谢的影响,以确保实验有效性.
相关概念视频
Preparation and Reactions of Sulfides
4.8K
Sulfides are the sulfur analog of ethers, just as thiols are the sulfur analog of alcohol. Like ethers, sulfides also consist of two hydrocarbon groups bonded to the central sulfur atom. Depending upon the type of groups present, sulfides can be symmetrical or asymmetrical. Symmetrical sulfides can be prepared via an SN2 reaction between 2 equivalents of an alkyl halide and one equivalent of sodium sulfide.
4.8K
Sample Preparation for Analysis: Advanced Techniques
326
Accurate analysis of complex samples often requires advanced preparation techniques to achieve reliable and reproducible results. Samples containing inorganic or organic materials can be challenging to dissolve or decompose effectively. Standard sample preparation methods include acid digestion, fusion, dry ashing, and wet digestion.
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
326
Atomic Emission Spectroscopy: Interference
179
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
179