风力轮机变速箱故障诊断方法的研究,使用单数值分解和图形里埃变换
Lan Chen1, Xiangfeng Zhang1, Zhanxiang Li1
1College of Intelligent Manufacturing and Industrial Modernization, Xinjiang University, Urumchi 830017, China.
Sensors (Basel, Switzerland)
|May 25, 2024
概括
这项研究引入了一种新的变速箱故障诊断方法,使用单数值分解 (SVD) 和图形里埃变换 (GFT). 该技术可以准确地识别变速箱故障,即使在杂的环境中也是如此.
科学领域:
- 机械工程 机械工程
- 信号处理 信号处理
- 错误诊断 错误诊断 错误诊断 是一个
背景情况:
- 变速箱在恶劣条件下容易发生故障.
- 环境噪音严重阻碍了机械设备的准确故障诊断.
- 现有的方法往往忽略了单数值之间的相互关系,失去了关键的故障信息.
研究的目的:
- 开发一种强大的故障诊断方法,用于抗环境噪声的变速箱.
- 以有效地从轮振动信号中提取微妙的故障信息.
- 提高机械故障诊断的准确性和可靠性.
主要方法:
- 从振动信号中提取特征的单值分解 (SVD).
- 图形信号处理 (GSP) 从单数值构建图形信号,捕获拓关系.
- 图表里埃变换 (GFT) 用于提取光谱域中的断裂特征.
- 马哈拉诺比斯距离用于辨别和诊断不同的缺陷状态.
主要成果:
- 拟议的方法通过分析单数值之间的相互关系,有效地捕获微妙的故障信息.
- 图形信号处理和GFT能够在光谱领域进行强大的特征提取.
- 对轴承和轮故障的实验验证证证了增强的噪声强度.
- 即使在噪音较高的环境中,也可以实现变速箱故障的准确诊断.
结论:
- 集成SVD,GSP和GFT提供了一种强大的方法来诊断变速箱故障.
- 与传统技术相比,该方法在噪音条件下表现优越.
- 这种方法提高了关键机械系统故障诊断的可靠性.
相关概念视频
Wind Turbine Machine Models
122
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
122
Turbine-Governor Control
208
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
208
Power System Three-Phase Short Circuits
83
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
83
Three-Winding Transformers
223
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
223
The Swing Equation
388
The Swing Equation is a fundamental tool in power system dynamics, especially for analyzing the behavior of generating units like three-phase synchronous generators. This equation emerges from applying Newton's second law to the rotor of a generator, encompassing factors such as inertia, angular acceleration, and the interplay between mechanical and electrical torques.
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque...
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque...
388
Three-Phase Short Circuit—Unloaded Synchronous Machine
139
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
139