规范性计算机断层扫描 血管扫描 大动脉根,大动脉和大动脉的值 在儿童中
Rakesh Donthula1, Wen Li1, Archita Duvvada2
1the University of Texas McGovern Medical School at Houston.
Research square
|May 27, 2024
概括
这项研究提供了使用ECG启动的CTA对儿童大动脉结构的基本规范值. 这些发现确定了儿童心血管成像中正常生长和发育的关键参考范围.
科学领域:
- 小儿心血管成像学
- 医学成像分析分析 医学成像分析
- 生物医学工程 生物医学工程
背景情况:
- 对于心内和心外血管结构的规范性数据对于评估儿科生长至关重要.
- 目前关于电心电图带电脑断层扫描血管学 (CTA) 的规范性数据缺乏.
- 确定这些值有助于理解儿童的正常心血管发育.
研究的目的:
- 为了确定大动脉根,大动脉和大动脉的规范值,在儿童中使用ECG-gated CTA.
- 为儿科心血管评估提供参考数据集.
- 为了促进儿童患者心血管成像的解释.
主要方法:
- 对大动脉根,上升大动脉,大动脉门和下降大动脉的测量是在100名儿科患者的静脉缩和静脉缩时进行的.
- 用心电图启动的CTA扫描用于精确的血管测量.
- 应用了全度指数 (AE) 和身体表面积 (BSA^AE) 规范化方法来得出标准化值.
主要成果:
- 静脉心电图 (ECG) 导入的静脉心电图 (CTA) Z-分数计算了大动脉根,大动脉和大动脉.
- 创建了规范曲线,绘制与身体表面积 (BSA) 相关的测量值.
- 对所有测量参数计算了正常化的平均值,横截面积和标准偏差.
结论:
- 该研究成功地报告了儿科大动脉结构的缩和扩张心电图启动的CTA Z-分数.
- 对于大动脉根,大动脉和大动脉来说,与BSA相对的规范曲线已经确定.
- 这些发现为儿科心血管成像和临床评估提供了重要的参考数据.
更多相关视频
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
2.3K
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
18.3K
相关概念视频
The Arch of Aorta
638
The coronary arteries, originating from the ascending aorta, bifurcate from two sinuses located within the ascending aorta. Positioned just above the aortic semilunar valve, these sinuses house essential aortic baroreceptors and chemoreceptors, crucial for maintaining cardiac function. The left coronary artery and the right coronary artery branch off from the left posterior and anterior aortic sinuses, respectively.
Encircling the heart, the coronary arteries form a ring-like structure before...
Encircling the heart, the coronary arteries form a ring-like structure before...
638
Imaging Studies for Cardiovascular System III: X-Ray
173
The most common cardiovascular diagnostic test is an X-ray. It produces images of the heart, blood vessels, and adjacent structures.
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
173
Thoracic Aorta
457
The thoracic section of the aorta begins at the T5 vertebra and extends to the T12 level at the diaphragm, initially progressing through the mediastinum to the left of the spinal column. Throughout its course in the thoracic segment, the thoracic aorta emits various offshoots known collectively as visceral and parietal branches. The branches that predominantly supply blood to visceral organs are termed visceral branches and include bronchial, pericardial, esophageal, and mediastinal arteries,...
457
The Aorta
768
The aorta is the largest artery in the human body. It originates from the left ventricle of the heart and extends down to the abdomen, where it splits into two smaller arteries. Structurally, it can be divided into four main parts: the ascending aorta, the aortic arch, the thoracic aorta, and the abdominal aorta.
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
768
Computed Tomography
4.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.5K