通过对岛屿检测方法的全面审查和比较分析,提高分布式能源系统的电网弹性
Mangesh S Kulkarni1,2, Sachin Mishra2, Suresh Kumar Sudabattula2
1Sharad Institute of Technology College of Engineering, Yadrav, Maharashtra, India.
Scientific reports
|May 27, 2024
概括
将分布式能源 (DER) 与电网集成提供了好处,但存在意外孤立的风险. 本研究评估了岛屿检测方法 (IDM),以确保分布式能源系统的安全可靠运行.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 整合可再生能源的整合
背景情况:
- 分布式能源资源 (DER) 集成提供了诸如减少化石燃料使用和提高电网可靠性等好处.
- 意外的DER岛屿对人员和设备构成重大安全风险.
- 有效的岛屿检测方法 (IDM) 对于减轻这些风险至关重要.
研究的目的:
- 对现有的岛屿检测方法 (IDM) 进行全面评估.
- 为了清晰度,将IDM分为本地和远程方法.
- 为分布式能源系统提供比较分析以指导最佳IDM的选择.
主要方法:
- 将IDM分为本地 (总干部监测) 和远程 (基于通信) 的方法.
- 基于特定的性能标准对IDM进行比较评估.
- 分析包括不检测区 (NDZ),检测时间和电源质量影响在内的因素.
主要成果:
- 通过NDZ,检测持续时间和电源质量等关键性能指标对IDM的评估.
- 评估适用于多个DER操作的适用性和依赖X/R比率.
- 确定各种IDM的高效运行参数.
结论:
- 对比评估有助于选择最有效和适用的IDM.
- 有信息的决策支持分布式能源系统的安全和可靠运行.
- 这项研究有助于DER在配电网络中的安全整合.
相关概念视频
Zones of Protection
166
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
166
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Reclosers and Fuses
101
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
101
Power System Three-Phase Short Circuits
83
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
83
Fast Decoupled and DC Powerflow
187
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187
Line Protection with Impedance Relays
79
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
79